1800-A

From GRWiki
Revision as of 23:23, 15 May 2024 by Jerry (talk | contribs)
Jump to navigation Jump to search
General Radio 1800-A
Vacuum-Tube Voltmeter
General Radio 1800-A Vacuum-Tube Voltmeter

Available from 1948 to 1954

Manuals
Catalog History
 Document Year Page
Catalog L 1948 146
Catalog M 1951 169
Catalog N 1954 182
(All manuals in PDF format unless noted otherwise)

The General Radio 1800-A Vacuum-Tube Voltmeter was introduced in Catalog L (1948) and remained available through Catalog N (1954).

The Type 1800-A is a high impedance, high frequency voltmeter. It was designed to replace the 726-A peak reading voltmeter.

On the AC voltage ranges, except for the two lowest, it is essentially a peak reading instrument, but the scales are calibrated to give readings of r-m-s values of sinusoidal applied voltages. The upper frequency limit approaches 500 Mhz with corrections, approximately 100 MHz without. For DC measurements binding posts are provided for DC only along with a shorting strip for the open grid mode. For AC measurements a hard-wired UHF probe is provided, stored in the top compartment along with it's accessories. When in the storage position the probe plugs into the front panel binding posts where low frequency AC measurements are made. When UHF measurements are desired the probe is removed for direct connection, the nose piece can be removed to reduce probe capacitance. Also located in the top compartment is a 50 Ω disk resistor used to convert the probe impedance along with adapters for GR Type 274 and Type 774 coaxial connectors. The 1800-A utilizes two RCA type 9005 "Acorn" UHF diodes, the data sheet is below. Two range extension accessories were available, the Types 1800-P2 High-Frequency Multiplier and 1800-P3 Low-Frequency Multiplier.

https://www.ietlabs.com/genrad_history/genrad_museum says

While several popular General Radio VTVMs preceded and followed the Type 1800, this classic was probably the most famous.

It was announced in 1946 and designed by C. E. Woodward with suggestions from D. B. Sinclair who later became a GR President.

It measured both AC and DC voltages over wide voltage ranges and its rectifying probe allowed useful measurements to over 300 MHz.

Specifications

  • Voltage Range: 0.1 to 150 V AC in 6 ranges; .01 to 150 V DC in 6 ranges
  • Accuracy: DC and AC ±2% of full scale on 6 ranges; AC accuracy is for sinusoidal voltages
  • Input Impedance: at low frequencies AC input resistance 25 MΩ; higher frequencies see manual; DC input resistance is 10  MΩ or open grid, selectable

Links

Photos