1192-B: Difference between revisions

From GRWiki
Jump to navigation Jump to search
(Created page with "Type '''1192 Counter 50 MHz'''. ==Specifications== ==Links== ==Photos== <gallery> </gallery> Category:Frequency Standards and Meters")
 
No edit summary
Line 1: Line 1:
Type '''1192 Counter 50 MHz'''.
{{GR Product
|model=1192-B
|codes=
|class=frequency standards and meters
|summary=Counter
|image=GR 1192-B Close-up.jpg
|caption=General Radio 1192-B Counter
|series=1192
|introduced=1973
|discontinued=1978+
|designers=
|manuals=
* [[Media:GR 1192B Counter 1192-0110-A 10_1970.pdf|General Radio 1192-B Counter Manual 1192-0110-A 1970]]
{{Catalog History}}
}}
The {{Title|General Radio 1192-B Counter}} was introduced in {{Catalog 1973}} and remained available through {{Catalog 1978}}.
 
The Type 1192-B is an electronic digital counter with an upper limit of 50 MHz. It's designed to measure frequency, period, frequency ratio, time interval, and event counter. The 1192-B is updated version of [[1192]] with an increase from 30 MHz to 50 MHz.
 
There are two inputs available, the A or main input is located on the front panel with B input on the rear of the instrument. The A input features a three step attenuator and a variable trigger control with maximum frequency or 50 MHz. The B input is used for ratio measurements only or the insertion of an external time base. This input has 10 MHz frequency limit and fixed trigger level and attenuation. On the rear panel are located the start and stop inputs that compliment the front panel start/stop push button for  event counting. A front panel test push button is available for testing the logic, it does not check calibration. The time base calibration is accessible through a hole in the bottom of the case.
 
A scaler Type [[1157-B]] is available to raise the counter frequency to 500 MHz as separate instrument or combination instrument  the Type 1192-Z. The counter was available in 5, 6, or 7 digit models and accessory card that buffered the display and made available at the rear panel.


==Specifications==
==Specifications==
* '''Frequency Measurements:''' DC to 50 MHz
* '''Period Resolution:''' 0.1 μs
* '''Time Interval Resolution:''' 0.1 μs
* '''Impedance:''' 50 Ω / 27 pF channel A; 10 kΩ / 20 pF channel B


==Links==
==Links==
* [[Media:GR Exp 1192 07_1969.pdf|Experimenter July 1969 describing Type 1192]]




==Photos==
==Photos==
<gallery>
<gallery>
GR 1192-B Front.jpg
GR 1192-B Side View.jpg
GR 1192-B Case Open.jpg
GR 1192-B Inside Top.jpg
GR 1192-B Front Panel Rear.jpg
GR 1192-B Inside Rear.jpg
GR 1192-B Inside Top Front C.jpg
GR 1192-B Inside Top Rear B.jpg
GR 1192-B Rear Panel.jpg
GR 1192-B Inside Bottom.jpg
GR 1192-Z Front View.jpg|1192-Z
</gallery>
</gallery>


[[Category:Frequency Standards and Meters]]
[[Category:Frequency Standards and Meters]]

Revision as of 06:33, 12 May 2024

General Radio 1192-B
Counter
General Radio 1192-B Counter

Available from 1973 to 1978+

Manuals
Catalog History
 Document Year Page
Catalog73 1973 328
Catalog78 1978 242
(All manuals in PDF format unless noted otherwise)

The General Radio 1192-B Counter was introduced in Catalog 1973 and remained available through Catalog 1978.

The Type 1192-B is an electronic digital counter with an upper limit of 50 MHz. It's designed to measure frequency, period, frequency ratio, time interval, and event counter. The 1192-B is updated version of 1192 with an increase from 30 MHz to 50 MHz.

There are two inputs available, the A or main input is located on the front panel with B input on the rear of the instrument. The A input features a three step attenuator and a variable trigger control with maximum frequency or 50 MHz. The B input is used for ratio measurements only or the insertion of an external time base. This input has 10 MHz frequency limit and fixed trigger level and attenuation. On the rear panel are located the start and stop inputs that compliment the front panel start/stop push button for event counting. A front panel test push button is available for testing the logic, it does not check calibration. The time base calibration is accessible through a hole in the bottom of the case.

A scaler Type 1157-B is available to raise the counter frequency to 500 MHz as separate instrument or combination instrument the Type 1192-Z. The counter was available in 5, 6, or 7 digit models and accessory card that buffered the display and made available at the rear panel.


Specifications

  • Frequency Measurements: DC to 50 MHz
  • Period Resolution: 0.1 μs
  • Time Interval Resolution: 0.1 μs
  • Impedance: 50 Ω / 27 pF channel A; 10 kΩ / 20 pF channel B


Links


Photos