The {{Title|General Radio 1192-Z Counter}} was introduced in {{Catalog 1973}} and remained available through {{Catalog 1978}}.  
The {{Title|General Radio 1192-Z Counter}} was introduced in {{Catalog 1973}} and remained available through {{Catalog 1978}}.  


The 1192-Z is the combination of the Type [[1192-B]] Counter and [[1157-B]] Scaler, increading the counter upper limit to 500 MHz.
It is a combination of a [[1192-B|Type 1192-B Counter]] with a [[1157-B|1157-B Scaler]] (see these pages for details), increasing the counter's upper frequency limit to 500 MHz.
<br>For more information see Type [[1192-B]] Counter and [[1157-B]] Scaler articles.


==Specifications==
==Specifications==


* '''Frequency Measurements:''' DC to 500 MHz.
* '''Frequency Measurements:''' DC to 500 MHz
* '''Period Resolution:''' 0.1 μs
* '''Period Resolution:''' 0.1 μs
* '''Time Interval Resolution:''' 0.1 μs
* '''Time Interval Resolution:''' 0.1 μs
* '''Impedance Type 1192-B:''' 50 Ω / 27 pF channel A; 10 kΩ / 20 pF channel B
* '''Impedance Type 1192-B:''' 50 Ω / 27 pF channel A; 10 kΩ / 20 pF channel B


* '''Input Type 1157-B above 50 MHz
* '''Input Type 1157-B above 50 MHz

Latest revision as of 17:17, 16 November 2024

General Radio 1192-Z
Counter
General Radio 1192-Z Counter

Available from 1973 to 1978+

Manuals
Catalog History
 Document Year Page
Catalog73 1973 329
Catalog78 1978 243
(All manuals in PDF format unless noted otherwise)

The General Radio 1192-Z Counter was introduced in Catalog 1973 and remained available through Catalog 1978.

It is a combination of a Type 1192-B Counter with a 1157-B Scaler (see these pages for details), increasing the counter's upper frequency limit to 500 MHz.

Specifications

  • Frequency Measurements: DC to 500 MHz
  • Period Resolution: 0.1 μs
  • Time Interval Resolution: 0.1 μs
  • Impedance Type 1192-B: 50 Ω / 27 pF channel A; 10 kΩ / 20 pF channel B
  • Input Type 1157-B above 50 MHz
  • Sensitivity: 100 mVRMS, 300 mVp-p
  • Maximum Signal: 7VRMS (l W)
  • Impedance:50 Ω, ac coupled

Links