1800-B: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
Line 17: Line 17:
The {{Title|General Radio 1800-B Vacuum-Tube Voltmeter}} was introduced in {{Catalog O}} and remained available through {{Catalog Q}}.  
The {{Title|General Radio 1800-B Vacuum-Tube Voltmeter}} was introduced in {{Catalog O}} and remained available through {{Catalog Q}}.  


The Type 1800-B is a high impedance, high frequency voltmeter, an updated version of the [[1800-A|1899-A Vacuum-Tube Voltmeter]] with improved power supply, including a two-stage voltage regulator, and updated with the new GR-874 probe adapter.  
The Type 1800-B is a high impedance, high frequency voltmeter, an updated version of the [[1800-A|1800-A Vacuum-Tube Voltmeter]] with improved power supply, including a two-stage voltage regulator, and updated with the new GR-874 probe adapter.  


Two range extension accessories were available, the Types [[1800-P2|1800-P2 High-Frequency Multiplier]],  and the [[1800-P3|1800-P3 Low-Frequency Multiplier]].
Two range extension accessories were available, the Types [[1800-P2|1800-P2 High-Frequency Multiplier]],  and the [[1800-P3|1800-P3 Low-Frequency Multiplier]].

Latest revision as of 09:08, 9 July 2024

General Radio 1800-B
Vacuum-Tube Voltmeter
General Radio 1800-B Vacuum-Tube Voltmeter

Available from 1956 to 1961

Manuals
Catalog History
 Document Year Page
Catalog O 1956 128
Catalog P 1959 128
Catalog Q 1961 126
(All manuals in PDF format unless noted otherwise)

The General Radio 1800-B Vacuum-Tube Voltmeter was introduced in Catalog O (1956) and remained available through Catalog Q (1961).

The Type 1800-B is a high impedance, high frequency voltmeter, an updated version of the 1800-A Vacuum-Tube Voltmeter with improved power supply, including a two-stage voltage regulator, and updated with the new GR-874 probe adapter.

Two range extension accessories were available, the Types 1800-P2 High-Frequency Multiplier, and the 1800-P3 Low-Frequency Multiplier.

On the AC voltage ranges, except for the two lowest, the 1800-B is essentially a peak-reading instrument, but the scales are calibrated to give readings of RMS values of sinusoidal voltages. The upper frequency limit approaches 500 MHz with corrections, approximately 100 MHz without. For DC measurements, binding posts are provided along with a shorting strip for the open grid mode. For AC measurements, a hard-wired UHF probe is provided, stored in the top compartment along with its accessories. When in the storage position, the probe plugs into the front panel binding posts where low-frequency AC measurements are made. When UHF measurements are desired, the probe is removed for direct connection, the nose piece can be removed to reduce probe capacitance. Also located in the top compartment is a 50 Ω disk resistor used to convert the probe impedance, along with adapters for GR Type 274 and Type 874 coaxial connectors.

The 1800-B utilizes two RCA type 9005 "Acorn" UHF diodes (see data sheet below).

Specifications

  • Voltage Range: 0.1 to 150 V AC in 6 ranges; .01 to 150 V DC in 6 ranges
  • Accuracy: DC and AC ±2% of full scale on 6 ranges; AC accuracy is for sinusoidal voltages
  • Input Impedance: at low frequencies AC input resistance 25 MΩ; higher frequencies see manual; DC input resistance is 10 MΩ or open grid, selectable

Links

Photos