1263-C: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
Line 18: Line 18:
* [[Media:GRwiki  Catalog 1978.pdf|Catalog78 (1978)]], p.123
* [[Media:GRwiki  Catalog 1978.pdf|Catalog78 (1978)]], p.123
}}
}}
The {{Title|General Radio 1263-C Amplitude-Regulating Power Supply}} was introduced in 1968 Catalog T and remained available through Catalog78 1978.  
The {{Title|General Radio 1263-C Amplitude-Regulating Power Supply}} was introduced in {{Catalog T}} and remained available through {{Catalog 1978}}.  


The Type 1263-C power supply is designed to work with unit VHF and UHF oscillators. It's purpose is to maintain oscillator output at a set level regardless of frequency. This is accomplished by adjusting plate current supplied by the 1263-C. The level is set by a front panel control and read on the panel meter. This leveling of oscillator output facilitates response measurements and assists sweep operation.  Blanking jacks are provided to blank or cut of the oscillator output during return trace during swept operation.
The Type 1263-C power supply is designed to work with VHF and UHF [[unit oscillators]]. It maintains oscillator output at a set level regardless of frequency by adjusting plate current supplied by the 1263-C. The level is set by a front panel control and read on the panel meter. This leveling of oscillator output facilitates response measurements and assists sweep operation.  Blanking jacks are provided to blank or cut of the oscillator output during return trace in swept operation.
Modulation is provided by an internal 1 kHz square wave generator and separate cable. The [[874-VR]] is required
 
to monitor unit oscillator output.  
Modulation is provided by an internal 1 kHz square wave generator and separate cable. The [[874-VR]] is required to monitor unit oscillator output.  


==Specifications==
==Specifications==
   
   
* '''Rf Output Voltage:''' 0.2 to 2.0 V at 50 Ω
* '''RF Output Voltage:''' 0.2 to 2.0 V at 50 Ω
* '''Rf Output Regulation:''' Below 500 MHz, rf output ±5% with recommended Unit Oscillators  
* '''RF Output Regulation:''' RF output ±5% with recommended Unit Oscillators blow 500 MHz
* '''Modulation Frequency:''' 1-kc square-wave, adjustable ±5%
* '''Modulation Frequency:''' 1 kHz square-wave, adjustable ±5%
* '''Plate Supply Output:''' 0 to 300 volts at 30 mA
* '''Plate Supply Output:''' 0 to 300 V at 30 mA
* '''Heater Supply Output:''' 6 V at 0.5 amp, 5.4 V at 0.7 amp (1263-B)
* '''Heater Supply Output:''' 6 V at 0.5 A, 5.4 V at 0.7 A (1263-B)


==Links==
==Links==

Navigation menu