1217-P2

From GRWiki
Jump to navigation Jump to search
General Radio 1217-P2
Single-Pulse Trigger
General Radio 1217-P2 Single-Pulse Trigger

Available from 1963 to 1973

Manuals
  • Manual Needed.
Catalog History
 Document Year Page
Catalog R 1963 136
Catalog S 1965 164
Catalog T 1968 221
Catalog U 1970 251
Catalog73 1973 320
(All manuals in PDF format unless noted otherwise)

The General Radio 1217-P2 Single-Pulse Trigger was introduced in Catalog R (1963) and remained available through Catalog 1973.

The Type 1217-P2 is an accessory for the 1217 Series of pulse generators designed to manually trigger single pulses. It requires a 1.5 volt AA battery and terminates in Type 274-MB double plug. A push-button switch triggers the single pulse.

Specifications

  • Pulse Output Amplitude: -1.2 to -1.5 volts depending battery used, behind 200 kΩ
  • Upon switch closure: Rise to zero volt in approximately 20 ms
  • Upon switch opening: Fall to between -1.2 and -1.5 volls in approximately 20 ms
  • Battery: 1.5-volt penlite cell (AA)