1205-B: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{GR Product | {{GR Product | ||
|model=1205-B | |model=1205-B | ||
|codes=APPLY,1205-9702 | |||
|class=power supplies | |class=power supplies | ||
|summary=adjustable power supply | |summary=adjustable power supply | ||
Line 19: | Line 20: | ||
==Specifications== | ==Specifications== | ||
* '''DC OUTPUT''' | * '''DC OUTPUT''' | ||
* '''Voltage:''' 0 to 300 V continuously adjustable, | * '''Voltage:''' 0 to 300 V continuously adjustable, max. 200 mA | ||
* '''Regulation:''' No load to full load, 0.1 V; ±0.75 V change for ±10% change in line voltage | * '''Regulation:''' No load to full load, 0.1 V; ±0.75 V change for ±10% change in line voltage | ||
* '''BIAS OUTPUT''' | * '''BIAS OUTPUT''' | ||
* '''Voltage:''' -150 V | * '''Voltage:''' -150 V DC fixed, max. 5 mA | ||
* '''Regulation:''' No load to full load, 0.5 V; | * '''Regulation:''' No load to full load, 0.5 V; ≤2 V change for ±10% change in line voltage | ||
* '''Heater Supply:''' | * '''Heater Supply:''' | ||
* '''Unregulated AC Voltage:''' 2 circuits, each 6.3 V nominal, at 5 A, can be connected in series or parallel | * '''Unregulated AC Voltage:''' 2 circuits, each 6.3 V nominal, at 5 A, can be connected in series or parallel | ||
==Links== | ==Links== |
Revision as of 00:19, 13 April 2024
The General Radio 1205-B Variable Power Supply was introduced in Catalog P (1959) and remained available through Catalog S (1965).
The Type 1205-B is a general purpose variable power supply having three outputs; high voltage, bias supply and heater supplies capable of 6.3 V/10 A or 12.6 V/5 A. The high voltage is regulated and continuously variable up to 300 V at 200 mA and a fixed bias at -150 V at 5 mA maximum. The rear cover is fitted with a cooling fan with spring contacts simplifies service. Connecting unit instruments to the 1205-B is made with a connector on right side of the instrument.
Specifications
- DC OUTPUT
- Voltage: 0 to 300 V continuously adjustable, max. 200 mA
- Regulation: No load to full load, 0.1 V; ±0.75 V change for ±10% change in line voltage
- BIAS OUTPUT
- Voltage: -150 V DC fixed, max. 5 mA
- Regulation: No load to full load, 0.5 V; ≤2 V change for ±10% change in line voltage
- Heater Supply:
- Unregulated AC Voltage: 2 circuits, each 6.3 V nominal, at 5 A, can be connected in series or parallel