General Radio 1205-B
adjustable power supply
General Radio 1205-B Variable Power Supply

Available from 1959 to 1968

Manuals
(All manuals in PDF format unless noted otherwise)

The General Radio 1205-B Variable Power Supply was introduced in 1959 Catalog P and remained available through Catalog S 1968.


Specifications

  • DC OUTPUT
  • Voltage: 0 to 300 V continuously adjustable, at 200 mA max.
  • Regulation: No load to full load, 0.1 V; ±0.75 V change for ±10% change in line voltage.
  • BIAS OUTPUT
  • Voltage: -150 V dc fixed, at 5 mA max.
  • Regulation: No load to full load, 0.5 V; 2-V max change for ±10% change in line voltage
  • Heater Supply:
  • Unregulated AC Voltage: 2 circuits, each 6.3 V nominal, at 5 A, can be connected in series or parallel.

Links

Photos