Revision as of 03:06, 21 March 2024
The General Radio 1205-B Variable Power Supply was introduced in 1959 Catalog P and remained available through Catalog S 1968.
Specifications
- DC OUTPUT
- Voltage: 0 to 300 V continuously adjustable, at 200 mA max.
- Regulation: No load to full load, 0.1 V; ±0.75 V change for ±10% change in line voltage.
- BIAS OUTPUT
- Voltage: -150 V dc fixed, at 5 mA max.
- Regulation: No load to full load, 0.5 V; 2-V max change for ±10% change in line voltage
- Heater Supply:
- Unregulated AC Voltage: 2 circuits, each 6.3 V nominal, at 5 A, can be connected in series or parallel.