1650-A: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 34: Line 34:
* [[Henry P. Hall]], ''A New Universal Impedance Bridge''. [[Media:General Radio Experimenter Vol.33 No.3 March 1959.pdf|General Radio Experimenter Volume 33, No. 3, March 1959]], page 3.
* [[Henry P. Hall]], ''A New Universal Impedance Bridge''. [[Media:General Radio Experimenter Vol.33 No.3 March 1959.pdf|General Radio Experimenter Volume 33, No. 3, March 1959]], page 3.
* [https://www.ietlabs.com/pdf/application_notes/12-Henry%20Hall%20Digibridge%20Patent-Digibridge.pdf IET Labs Application Note, ''Henry Hall: Father of the Digibridge'']
* [https://www.ietlabs.com/pdf/application_notes/12-Henry%20Hall%20Digibridge%20Patent-Digibridge.pdf IET Labs Application Note, ''Henry Hall: Father of the Digibridge'']
'''Videos'''
* [https://www.youtube.com/watch?v=Id9wMgjEQ04 General Radio Genrad 1650 impedance bridge - Oscillator Circuit repair and calibration] @ YouTube
* [https://www.youtube.com/watch?v=VMFOWfUiLLw General Radio 1650-A Experimentation with Coils Capacitors and Tank circuits] @ YouTube
* [https://www.youtube.com/watch?v=96G_VjkvvnE Vacuum Tube Audio Transformer Impedance Determined With General Radio Impedance Bridge] @ YouTube


==Pictures==
==Pictures==

Revision as of 15:44, 18 March 2024

General Radio 1650-A
portable impedance bridge
Genrad 1650-A Bridge

Available from 1959 to (?)

Manuals

The General Radio 1650-A is a portable impedance bridge introduced in 1959. It was succeeded by the 1650-B in 1968.

The 1650 has an "Orthonull" feature, which is a mechanical link driving the DQ dial from the CRL dials through a friction clutch. It helps avoid the "sliding null" problem when measuring components with high losses.

Key Specifications

  • Capacitance: 1 pF to 1100 μF in 7 ranges.
  • Inductance: 1 μH to 1100 H in 7 ranges
  • Resistance: 1 mΩ to 11 MΩ in 8 ranges
  • D: (series capacitance) 0.001 to 1 at 1 kHz, (parallel capacitance) 0.1 to 50 at 1 kHz
  • Q: (series inductance) 0.02 to 10 at 1 kHz, (parallel inductance) 1 to 1000 at 1 kHz
  • Basic accuracy: ±1% of full scale, ±5% for dissipation factor
  • Internal oscillator: 1 kHz ±2%
  • Frequency range: 20 Hz to 20 kHz (to 100 kHz with reduced accuracy)