* '''Deviation Range:''' Impedance difference, ±5% and ±20%, switched. Disipation factor difference, ±.006 at 400 Hz. ±.015 at 1 kHz. ±.075 at 5 kHz.
* '''Deviation Range:''' Impedance difference, ±5% and ±20%, switched. Dissipation factor difference, ±0.006 at 400 Hz, ±0.015 at 1 kHz, ±0.075 at 5 kHz
* '''Test Frequency:''' 400 Hz, 1 kHz, and 5 kHz; The frequency is within ±3% of the nominal value.
* '''Test Frequency:''' 400 Hz, 1 kHz, and 5 kHz within ±3%
* '''Voltage Applied to Unknown:''' Approximately one volt, for impedances above 500 Ω. For lower values of impedance the voltage is decreased.
* '''Voltage Applied to Unknown:''' Approximately 1 V for impedances above 500 Ω. For lower values of impedance the voltage is decreased.


==Links==
==Links==

Revision as of 19:30, 30 March 2024

General Radio 1604-B
comparison bridge
General Radio 1604-B Comparison Bridge

Available from 1954 to 1956

Manuals
Catalog History
 Document Year Page
Catalog N 1954 93
Catalog O 1956 31
(All manuals in PDF format unless noted otherwise)

The General Radio 1604-B Comparison Bridge was introduced in 1954 Catalog N and remained available through Catalog O 1956.

The General Radio 1604-B Comparison Bridge was introduced in 1954 Catalog N and remained available through Catalog O 1956. The Type 1604-B was designed for sorting, adjusting and comparing two devices at three different frequencies.

Impedance difference is measured in two ranges, 5% or 20% selected by a front panel switch, using a built generator and detector equipped with a 2AP1 CRT. A balance is achieved when the vertical deflection is at a minimum.

Dissipation factor difference is read directly from the dial in one range. The main change from the 1604-A is the addition of a 400 Hz test frequency.