1652-A: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 14: | Line 14: | ||
The '''General Radio 1652-A Resistance Limit Bridge''' was introduced in 1951 Catalog M and remained available through Catalog T 1968. | The '''General Radio 1652-A Resistance Limit Bridge''' was introduced in 1951 Catalog M and remained available through Catalog T 1968. | ||
Based on a [[wikipedia:Wheatstone bridge|Wheatstone bridge]] circuit, the Type 1652-A will compare the unknown to an external or internal standard and display difference as a percentage. | |||
Its internal standard is made up of seven [[510|Type 510 Decade Resistance]] units connected in series. | |||
==Specifications== | ==Specifications== | ||
* '''Resistance Range:''' As a limit bridge, 1 ohm to 1,111,111 ohms with internal standard; for null measurement, 1 ohm to 1,111,111 ohms with internal standard | * '''Resistance Range:''' As a limit bridge, 1 ohm to 1,111,111 ohms with internal standard; for null measurement, 1 ohm to 1,111,111 ohms with internal standard | ||
* '''Voltage Applied to Unknown:''' The voltage across the unknown one volt when the meter indication is zero. | * '''Voltage Applied to Unknown:''' The voltage across the unknown one volt when the meter indication is zero. | ||
* '''Accuracy:''' As a limit bridge, ±0.5% or better; for matching, ±0.2% | * '''Accuracy:''' As a limit bridge, ±0.5% or better; for matching, ±0.2% | ||
* '''Limit Range:''' Meter reads from | * '''Limit Range:''' Meter reads from –20% to +20% | ||
==Links== | ==Links== |
Revision as of 18:35, 16 March 2024
The General Radio 1652-A Resistance Limit Bridge was introduced in 1951 Catalog M and remained available through Catalog T 1968.
Based on a Wheatstone bridge circuit, the Type 1652-A will compare the unknown to an external or internal standard and display difference as a percentage. Its internal standard is made up of seven Type 510 Decade Resistance units connected in series.
Specifications
- Resistance Range: As a limit bridge, 1 ohm to 1,111,111 ohms with internal standard; for null measurement, 1 ohm to 1,111,111 ohms with internal standard
- Voltage Applied to Unknown: The voltage across the unknown one volt when the meter indication is zero.
- Accuracy: As a limit bridge, ±0.5% or better; for matching, ±0.2%
- Limit Range: Meter reads from –20% to +20%