1652-A: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 14: Line 14:
The '''General Radio 1652-A Resistance Limit Bridge''' was introduced in 1951 Catalog M and remained available through Catalog T 1968.
The '''General Radio 1652-A Resistance Limit Bridge''' was introduced in 1951 Catalog M and remained available through Catalog T 1968.


Using the Weatstone bridge the Type 1652-A will compare the unknown to an external or internal standard and display difference as a percentage.  It's internal standard is made up of seven Type [[510]] Decade Resistance units connected in series.
Based on a [[wikipedia:Wheatstone bridge|Wheatstone bridge]] circuit, the Type 1652-A will compare the unknown to an external or internal standard and display difference as a percentage.   
Its internal standard is made up of seven [[510|Type 510 Decade Resistance]] units connected in series.


==Specifications==
==Specifications==
* '''Resistance Range:''' As a limit bridge, 1 ohm to 1,111,111 ohms with internal standard; for null measurement, 1 ohm to 1,111,111 ohms with internal standard.
* '''Resistance Range:''' As a limit bridge, 1 ohm to 1,111,111 ohms with internal standard; for null measurement, 1 ohm to 1,111,111 ohms with internal standard
* '''Voltage Applied to Unknown:''' The voltage across the unknown one volt when the meter indication is zero.
* '''Voltage Applied to Unknown:''' The voltage across the unknown one volt when the meter indication is zero.
* '''Accuracy:''' As a limit bridge, ±0.5% or better; for matching, ±0.2%.
* '''Accuracy:''' As a limit bridge, ±0.5% or better; for matching, ±0.2%
* '''Limit Range:''' Meter reads from -20% to +20%.
* '''Limit Range:''' Meter reads from –20% to +20%


==Links==
==Links==

Revision as of 18:35, 16 March 2024

General Radio 1652-A
resistance limit bridge
General Radio 1652-A Resistance Limit Bridge

Available from 1951 to 1968

Manuals
(All manuals in PDF format unless noted otherwise)

The General Radio 1652-A Resistance Limit Bridge was introduced in 1951 Catalog M and remained available through Catalog T 1968.

Based on a Wheatstone bridge circuit, the Type 1652-A will compare the unknown to an external or internal standard and display difference as a percentage. Its internal standard is made up of seven Type 510 Decade Resistance units connected in series.

Specifications

  • Resistance Range: As a limit bridge, 1 ohm to 1,111,111 ohms with internal standard; for null measurement, 1 ohm to 1,111,111 ohms with internal standard
  • Voltage Applied to Unknown: The voltage across the unknown one volt when the meter indication is zero.
  • Accuracy: As a limit bridge, ±0.5% or better; for matching, ±0.2%
  • Limit Range: Meter reads from –20% to +20%