1604-B: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 12: Line 12:
* [[Media:GR 1604-B Impedance Comparison Bridge 790-B 1956.pdf|General Radio 1604-B Impedance Comparison Bridge 790-B 1956]]
* [[Media:GR 1604-B Impedance Comparison Bridge 790-B 1956.pdf|General Radio 1604-B Impedance Comparison Bridge 790-B 1956]]
}}
}}
The '''General Radio 1604-B Comparison Bridge''' was introduced in 1954 Catalog N and remained available through Catalog O 1956.
The '''General Radio 1604-B Comparison Bridge''' was introduced in 1954 Catalog N and remained available through Catalog O 1956. The '''General Radio 1604-B Comparison Bridge''' was introduced in 1954 Catalog N and remained available through Catalog O 1956.
The Type 1604-B was designed for sorting, adjusting and comparing two devices at three different frequencies.  Impedance difference is measured in two ranges 5% and 20% using front panel switch, using a built generator and detector equiped with a 2AP1 CRT.  A balance is achieved when the vertical deflection is at a minimum. Disipation factor difference is read directly from the dial, one range.  The main change from the [[1604-A]] is the addition of the 400 Hz test frequency.
 


==Specifications==
==Specifications==

Revision as of 01:45, 7 March 2024

General Radio 1604-B
comparison bridge
General Radio 1604-B Comparison Bridge

Available from 1954 to 1956

Manuals
(All manuals in PDF format unless noted otherwise)

The General Radio 1604-B Comparison Bridge was introduced in 1954 Catalog N and remained available through Catalog O 1956. The General Radio 1604-B Comparison Bridge was introduced in 1954 Catalog N and remained available through Catalog O 1956. The Type 1604-B was designed for sorting, adjusting and comparing two devices at three different frequencies. Impedance difference is measured in two ranges 5% and 20% using front panel switch, using a built generator and detector equiped with a 2AP1 CRT. A balance is achieved when the vertical deflection is at a minimum. Disipation factor difference is read directly from the dial, one range. The main change from the 1604-A is the addition of the 400 Hz test frequency.


Specifications

  • Deviation Range: Impedance difference, ±5% and ±20%, switched. Disipation factor difference, ±.006 at 400 Hz. ±.015 at 1 kHz. ±.075 at 5 kHz.
  • Test Frequency: 400 Hz, 1 kHz, and 5 kHz; The frequency is within ±3% of the nominal value.
  • Voltage Applied to Unknown: Approximately one volt, for impedances above 500 Ω. For lower values of impedance the voltage is decreased.

Links

Photos