1800-P3: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{GR Product
{{GR Product
|model=1800-P3
|model=1800-P3
|codes=ABEAM
|class=meters
|class=meters
|summary=Low-Frequency Multiplier
|summary=Low-Frequency Multiplier
Line 15: Line 16:
The {{Title|General Radio 1800-P3 Low-Frequency Multiplier}} was introduced in {{Catalog M}} and remained available through {{Catalog Q}}.  
The {{Title|General Radio 1800-P3 Low-Frequency Multiplier}} was introduced in {{Catalog M}} and remained available through {{Catalog Q}}.  


The Type 1800-P3 is an accessory for the Type [[1800-A]] voltmeter designed to increase the input voltage range to 1500 volts. The  multiplier is not recommended for use above 100 kHz unless adjusted for use at a fixed frequency. Above 100 kHz the Type [[1800-P2]] multiplier is recommended.
The Type 1800-P3 is an accessory for the [[1800-A|Type 1800-A Voltmeter]], a compensated 10:1 voltage divider designed to increase the input voltage range to 1500 V.  
The  multiplier is not recommended for use above 100 kHz unless adjusted for use at a fixed frequency.  
Above 100 kHz, the [[1800-P2|Type 1800-P2 Multiplier]] is recommended.


The multiplier attaches to the [[1800-A]] probe observing the connections displayed at the output of the multiplier.
The multiplier attaches to the [[1800-A]] probe observing the connections displayed at the output of the multiplier.
Line 23: Line 26:
* '''Multiplier Ratio DC:''' 10:1 ±1%
* '''Multiplier Ratio DC:''' 10:1 ±1%
* '''Multiplier Ratio AC:''' 10:1 ±0.5%
* '''Multiplier Ratio AC:''' 10:1 ±0.5%
* '''Input Impedance:''' DC 10 MΩ; AC 10 MΩ parallel resistance,with 10 pF parallel capacitance
* '''Input Impedance:''' DC 10 MΩ; AC 10 MΩ // 10 pF


==Links==
==Links==

Latest revision as of 19:29, 30 May 2024

General Radio 1800-P3
Low-Frequency Multiplier
General Radio 1800-P3 Low-Frequency Multiplier

Available from 1951 to 1961

Manuals
Catalog History
 Document Year Page
Catalog M 1951 171
Catalog N 1954 185
Catalog O 1956 131
Catalog P 1959 128
Catalog Q 1961 127
(All manuals in PDF format unless noted otherwise)

The General Radio 1800-P3 Low-Frequency Multiplier was introduced in Catalog M (1951) and remained available through Catalog Q (1961).

The Type 1800-P3 is an accessory for the Type 1800-A Voltmeter, a compensated 10:1 voltage divider designed to increase the input voltage range to 1500 V. The multiplier is not recommended for use above 100 kHz unless adjusted for use at a fixed frequency. Above 100 kHz, the Type 1800-P2 Multiplier is recommended.

The multiplier attaches to the 1800-A probe observing the connections displayed at the output of the multiplier.

Specifications

  • Multiplier Ratio DC: 10:1 ±1%
  • Multiplier Ratio AC: 10:1 ±0.5%
  • Input Impedance: DC 10 MΩ; AC 10 MΩ // 10 pF

Links

Photos