874-LBA: Difference between revisions

From GRWiki
Jump to navigation Jump to search
(Created page with "Type '''874-LBA Slotted Line'''. ==Specifications== ==Links== ==Photos== <gallery> </gallery> Category:Coaxial Elements Category:GR-874")
 
 
(12 intermediate revisions by 2 users not shown)
Line 1: Line 1:
Type '''874-LBA Slotted Line'''.
{{GR Product
|model=874-LBA
|codes=COAXRUNNER
|class=coaxial elements
|summary=Slotted Line
|image=GR 874-LBA Close-up.jpg
|caption=General Radio 874-LBA Slotted Line
|series=GR-874
|introduced=1956
|discontinued=1965
|designers=
|manuals=
* [[Media:GR 874-LLA_LLB Slotted Line 0874-0215-I 04_1966.pdf|General Radio 874-LBA/874-LBB Slotted Line Manual 0874-0215-I 1966]]
{{Catalog History}}
}}
The {{Title|General Radio 874-LBA Slotted Line}} was introduced in {{Catalog O}} and remained available through {{Catalog S}}.  Its function is to observe the electric field along the inside of a coaxial transmission line using a carriage-mounted probe moving along the line. 
 
By observing minima and maxima of a standing-wave pattern, parameters like frequency, standing-wave ratio, or impedance can be measured, and thereby the characteristics of a circuit connected to the load side of the line can be determined.  Applications include analysis of antennas, components, coaxial elements, and networks. 
 
The 874-LBA is an update of the [[874-LB]], featuring improved accuracy and carriage construction. The redesigned carriage is controlled by a nylon cord forming a complete loop, and a series of pulleys to remove its drive control to a fixed position at the load end.  This reduces changes in probe coupling caused by changing forces on the carriage.  An optional [[874-LV|874-LV Micrometer Vernier]] can be attached for high-resolution measurements.
 
The 874-LBA was supplied with a protective wooden case, a spare nylon cable, and a crystal detector.  


==Specifications==
==Specifications==
* '''Characteristic Impedance:''' 50 Ω, ±0.5%
* '''Scale Accuracy:''' ±(0.1 mm +0.05%)
* '''Frequency Range:''' 300 MHz to 5 GHz; for measurements below 300 MHz, add [[874-L30]] air line sections
* '''Length:''' 50 cm probe travel (λ/2 @ 300 MHz, λ/4 @ 150 MHz)
* '''Constancy of Probe Penetration:''' ±1½%
* '''Residual SWR:''' 1.025 @ 1 GHz, 1.07 @ 4 GHz


==Links==
==Links==


* [[Media:GR Exp 874-LBA 12_1954.pdf|Experimenter December 1954 describing Type 874-LBA]]
* [[Media:1N Series Microwave Diode Data Sheet.pdf|1N23B Microwave Diode Data]]
* [[Media:Handbook of Coaxial Microwave Measurements.pdf|Handbook of Coaxial Microwave Measurements]]
* [https://www.youtube.com/watch?v=DovunOxlY1k&t=668s AT&T Archives Wave Machine Tutorial] @ YouTube
* Predecessor: [[874-LB]]
* Successor: [[874-LBB]] (8.5 GHz)


==Photos==
==Photos==
<gallery>
<gallery>
GR 874-LBA Case Closed.jpg
GR 874-LBA Case Open.jpg
GR 874-LBA Case empty.jpg
GR 874-LBA Spare Probe Rectifier.jpg
GR 874-LBA Front A.jpg
GR 874-LBA Front.jpg
GR 874-LBA Input Oscillator Side A.jpg
GR 874-LBA Input Oscillator Side.jpg
GR 874-LBA Carriage B.jpg
GR 874-LBA Carriage A.jpg
GR 874-LBA 874-LV Micrometer.jpg
GR 874-LBA Rear.jpg
GR 874-LBA Right Side.jpg
GR 874-LBA Termination Side.jpg
</gallery>
</gallery>


[[Category:Coaxial Elements]]
[[Category:Coaxial Elements]]
[[Category:GR-874]]
[[Category:GR-874]]

Latest revision as of 18:12, 30 May 2024

General Radio 874-LBA
Slotted Line
General Radio 874-LBA Slotted Line

Available from 1956 to 1965

Manuals
Catalog History
 Document Year Page
Catalog O 1956 46
Catalog P 1959 43
Catalog Q 1961 52
Catalog R 1963 65
Catalog S 1965 82
(All manuals in PDF format unless noted otherwise)

The General Radio 874-LBA Slotted Line was introduced in Catalog O (1956) and remained available through Catalog S (1965). Its function is to observe the electric field along the inside of a coaxial transmission line using a carriage-mounted probe moving along the line.

By observing minima and maxima of a standing-wave pattern, parameters like frequency, standing-wave ratio, or impedance can be measured, and thereby the characteristics of a circuit connected to the load side of the line can be determined. Applications include analysis of antennas, components, coaxial elements, and networks.

The 874-LBA is an update of the 874-LB, featuring improved accuracy and carriage construction. The redesigned carriage is controlled by a nylon cord forming a complete loop, and a series of pulleys to remove its drive control to a fixed position at the load end. This reduces changes in probe coupling caused by changing forces on the carriage. An optional 874-LV Micrometer Vernier can be attached for high-resolution measurements.

The 874-LBA was supplied with a protective wooden case, a spare nylon cable, and a crystal detector.

Specifications

  • Characteristic Impedance: 50 Ω, ±0.5%
  • Scale Accuracy: ±(0.1 mm +0.05%)
  • Frequency Range: 300 MHz to 5 GHz; for measurements below 300 MHz, add 874-L30 air line sections
  • Length: 50 cm probe travel (λ/2 @ 300 MHz, λ/4 @ 150 MHz)
  • Constancy of Probe Penetration: ±1½%
  • Residual SWR: 1.025 @ 1 GHz, 1.07 @ 4 GHz

Links