1203-B: Difference between revisions

From GRWiki
Jump to navigation Jump to search
(Created page with "Type '''1203-B Unit Power Supply'''. ==Specifications== ==Links== ==Photos== <gallery> </gallery> Category:Power Supplies Category:Unit Instruments")
 
No edit summary
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
Type '''1203-B Unit Power Supply'''.
{{GR Product
|model=1203-B
|codes=ALIVE,ALIVERALLY,ALIVEREGAL
|class=power supplies
|summary=Unit Power Supply
|image=GR 1203-B Close-up.jpg
|caption=General Radio 1203-B Unit Power Supply
|series=
|introduced=1956
|discontinued=1965
|designers=
|manuals=
* [[Media:GR 1203-B Power Supply 754-D 04_1959.pdf|General Radio 1203-B Unit Power Supply Manual 754-D 1959]]
{{Catalog History}}
}}
The {{Title|General Radio 1203-B Unit Power Supply}} was introduced in {{Catalog O}} and remained available through {{Catalog S}}. 
It is a general-purpose unit type power supply, an updated version of the [[1203-A]] with improved high-voltage filtering and a case redesign that moved the fuse holders to the front panel.
 
There are separate versions for 105-125 V / 210-250 V line voltage.
The 300 V output is unregulated, as is the filament supply. Both power supplies are isolated from ground.
 
With its five-pin power connector located on the right side panel, the 1203-B is compatible with most [[unit instruments]].


==Specifications==
==Specifications==
* '''Outputs'''
* '''High Voltage:''' 300 V<sub>DC</sub> at 50 mA
* '''Filament Voltage:''' 6.3 V<sub>AC</sub> at 3 A (unregulated)
* '''Ripple:''' Less than 80 mV<sub>RMS</sub> at full load, 120 Hz


==Links==
==Links==


* [[Media:GR Exp 1203-B 07_1957.pdf|Experimenter July 1957 describing Type 1203-B]]


==Photos==
==Photos==
<gallery>
<gallery>
GR 1203-B Front.jpg
GR 1203-B Left.jpg
GR 1203-B Rear.jpg
GR 1203-B Right.jpg
GR 1203-B Inside Top.jpg
GR 1203-B Inside Rear.jpg
GR 1203-B Inside Bottom.jpg
</gallery>
</gallery>


[[Category:Power Supplies]]
[[Category:Power Supplies]]
[[Category:Unit Instruments]]
[[Category:Unit Instruments]]

Latest revision as of 03:45, 14 May 2024

General Radio 1203-B
Unit Power Supply
General Radio 1203-B Unit Power Supply

Available from 1956 to 1965

Manuals
Catalog History
 Document Year Page
Catalog O 1956 144
Catalog P 1959 143
Catalog Q 1961 137
Catalog R 1963 173
Catalog S 1965 219
(All manuals in PDF format unless noted otherwise)

The General Radio 1203-B Unit Power Supply was introduced in Catalog O (1956) and remained available through Catalog S (1965). It is a general-purpose unit type power supply, an updated version of the 1203-A with improved high-voltage filtering and a case redesign that moved the fuse holders to the front panel.

There are separate versions for 105-125 V / 210-250 V line voltage. The 300 V output is unregulated, as is the filament supply. Both power supplies are isolated from ground.

With its five-pin power connector located on the right side panel, the 1203-B is compatible with most unit instruments.

Specifications

  • Outputs
  • High Voltage: 300 VDC at 50 mA
  • Filament Voltage: 6.3 VAC at 3 A (unregulated)
  • Ripple: Less than 80 mVRMS at full load, 120 Hz

Links

Photos