1205-B: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{GR Product
{{GR Product
|model=1205-B
|model=1205-B
|codes=APPLY,1205-9702
|class=power supplies
|class=power supplies
|summary=adjustable power supply
|summary=Adjustable power supply
|image=GR 1205-B Front Close-Up.jpg
|image=GR 1205-B Front Close-Up.jpg
|caption=General Radio 1205-B Variable Power Supply
|caption=General Radio 1205-B Variable Power Supply
Line 11: Line 12:
|manuals=
|manuals=
* [[Media:GRwiki 1205-B Variable PS 1205-0100-C 04_1965.pdf|General Radio 1205-B Variable Power Supply Manual 1205-0100-C 1965]]
* [[Media:GRwiki 1205-B Variable PS 1205-0100-C 04_1965.pdf|General Radio 1205-B Variable Power Supply Manual 1205-0100-C 1965]]
{{Catalog History}}
}}
}}
The '''General Radio 1205-B Variable Power Supply''' was introduced in {{Catalog P}} and remained available through {{Catalog S}.  
The {{Title|General Radio 1205-B Variable Power Supply}} was introduced in {{Catalog P}} and remained available through {{Catalog S}}.  


The Type 1205-B is a general purpose variable power supply having three outputs; high voltage, bias supply and heater supplies capable of 6.3 V/10 A or 12.6 V/5 A. The high voltage is regulated and continuously variable up to 300 V at 200 mA and a fixed bias at -150 V at 5 mA maximum. The rear cover is fitted with a cooling fan with spring contacts simplifies service.  Connecting unit instruments to the 1205-B is made with a connector on right side of the instrument.  
It is a general-purpose, variable power supply having three outputs; high voltage, bias supply and heater.
The high voltage is regulated and continuously variable up to 300 V at 200 mA, the fixed bias supply provides –150 V at 5 mA maximum.  
The heater supply is capable of 6.3 V/10 A or 12.6 V/5 A.
 
The rear cover is fitted with a cooling fan with spring contacts to simplify service.   
Unit instruments connect to the 1205-B through a connector on the right side of the instrument.  


==Specifications==
==Specifications==
* '''DC OUTPUT'''
* '''DC OUTPUT'''
* '''Voltage:''' 0 to 300 V continuously adjustable, at 200 mA max.
* '''Voltage:''' 0 to 300 V continuously adjustable, max. 200 mA
* '''Regulation:''' No load to full load, 0.1 V; ±0.75 V change for ±10% change in line voltage.
* '''Regulation:''' No load to full load, 0.1 V; ±0.75 V change for ±10% change in line voltage
* '''BIAS OUTPUT'''
* '''BIAS OUTPUT'''
* '''Voltage:''' -150 V dc fixed, at 5 mA max.
* '''Voltage:''' -150 V DC fixed, max. 5 mA
* '''Regulation:''' No load to full load, 0.5 V; 2-V max change for ±10% change in line voltage
* '''Regulation:''' No load to full load, 0.5 V; ≤2 V change for ±10% change in line voltage
* '''Heater Supply:'''
* '''Heater Supply:'''
* '''Unregulated AC Voltage:''' 2 circuits, each 6.3 V nominal, at 5 A, can be connected in series or parallel.
* '''Unregulated AC Voltage:''' 2 circuits, each 6.3 V nominal, at 5 A, can be connected in series or parallel


==Links==
==Links==


* [[Media:GR Exp 1205-B 03_1959.pdf|Experimenter describing Type 1205-B March 1959]]
* [[Media:GR Exp 1205-B 03_1959.pdf|Experimenter March 1959 describing Type 1205-B]]


==Photos==
==Photos==

Latest revision as of 23:17, 30 April 2024

General Radio 1205-B
Adjustable power supply
General Radio 1205-B Variable Power Supply

Available from 1959 to 1968

Manuals
Catalog History
 Document Year Page
Catalog P 1959 142
Catalog Q 1961 136
Catalog R 1963 172
Catalog S 1965 218
(All manuals in PDF format unless noted otherwise)

The General Radio 1205-B Variable Power Supply was introduced in Catalog P (1959) and remained available through Catalog S (1965).

It is a general-purpose, variable power supply having three outputs; high voltage, bias supply and heater. The high voltage is regulated and continuously variable up to 300 V at 200 mA, the fixed bias supply provides –150 V at 5 mA maximum. The heater supply is capable of 6.3 V/10 A or 12.6 V/5 A.

The rear cover is fitted with a cooling fan with spring contacts to simplify service. Unit instruments connect to the 1205-B through a connector on the right side of the instrument.

Specifications

  • DC OUTPUT
  • Voltage: 0 to 300 V continuously adjustable, max. 200 mA
  • Regulation: No load to full load, 0.1 V; ±0.75 V change for ±10% change in line voltage
  • BIAS OUTPUT
  • Voltage: -150 V DC fixed, max. 5 mA
  • Regulation: No load to full load, 0.5 V; ≤2 V change for ±10% change in line voltage
  • Heater Supply:
  • Unregulated AC Voltage: 2 circuits, each 6.3 V nominal, at 5 A, can be connected in series or parallel

Links