The '''General Radio 358 Amateur Band Wavemeter''' was introduced in {{Bulletin 926}} and remained available through {{Catalog K1}}.
The '''General Radio 358 Amateur Band Wavemeter''' was introduced in {{Bulletin 926}} and remained available through {{Catalog K1}}.


The Type 358 is an absorption type wavemeter covering the four overlapping bands.  It has an frequency accuracy of 1% and uses an incandescent lamp as a resonance indicator.  The lamp is in a special socket that closes the connection when the lamp is removed if not needed. A Type [[247]] gear driven condenser is used inside the meter. Each wavemeter is supplied with a calibration chart produced with settings accurate for that particular meter.  
The Type 358 is an absorption type wavemeter covering the four overlapping bands.  It has an frequency accuracy of 1% and uses an incandescent lamp as a resonance indicator.  The lamp is in a special socket that closes the connection when the lamp is removed if not needed. A Type 247 gear driven condenser is used inside the meter. Each wavemeter is supplied with a calibration chart produced with settings accurate for that particular meter.  


==Specifications==
==Specifications==

Revision as of 23:29, 3 April 2024

General Radio 358
amateur band wavemeter
General Radio 358 Amateur Band Wavemeter

Available from 1924 to 1939

Manuals
  • Manual Needed
Catalog History
 Document Year Page
Bulletin 926 1924 9251
Bulletin 930 1928 9373
Catalog E1 1928 78
Catalog E2 1928 78
Catalog F1 1930 69
Bulletin 933 1931 26
Catalog G1 1932 64
Bulletin 936 1935 24
Catalog H 1935 152
Catalog J 1936 60
Catalog K1 1939 164
(All manuals in PDF format unless noted otherwise)

The General Radio 358 Amateur Band Wavemeter was introduced in Bulletin 926 (1924) and remained available through Catalog K1 (1939).

The Type 358 is an absorption type wavemeter covering the four overlapping bands. It has an frequency accuracy of 1% and uses an incandescent lamp as a resonance indicator. The lamp is in a special socket that closes the connection when the lamp is removed if not needed. A Type 247 gear driven condenser is used inside the meter. Each wavemeter is supplied with a calibration chart produced with settings accurate for that particular meter.

Specifications

  • Frequency Ranges
  • Wavelength: 14 to 28 Meters, 26 to 56 Meters, 54 to 114 Meters, 105 to 220 Meters
  • Frequency: 10.0 to 20.0 MHz, 5.0 to 10.0 Mhz, 2.5 to 5.0 MHz, 1.5 to 3.0 MHz
  • Accuracy: 1%

Links

Photos