1134-A: Difference between revisions

Jump to navigation Jump to search
no edit summary
No edit summary
No edit summary
Line 2: Line 2:
|model=1134-A
|model=1134-A
|class=frequency standards and meters
|class=frequency standards and meters
|summary=Analog to Digital Converter
|summary=Analog to digital converter
|image=GR 1134-A Close-up.jpg
|image=GR 1134-A Close-up.jpg
|caption=General Radio 1134-A Analog to Digital Converter
|caption=General Radio 1134-A Analog to Digital Converter
Line 11: Line 11:
|manuals=
|manuals=
* '''Manual Needed'''
* '''Manual Needed'''
* [[Media:GR 1130A Digital Frequency Meter 1130-0110-A 11_1965.pdf|Type GR 1130A Digital Frequency Meter Manual 1130-0110-A 11_1965]]
{{Catalog History}}
{{Catalog History}}
}}
}}
The {{Title|General Radio 1134-A Analog to Digital Converter}} was introduced in {{Catalog Q}} and remained available through {{Catalog R}}.  
The {{Title|General Radio 1134-A Analog to Digital Converter}} was introduced in {{Catalog Q}} and remained available through {{Catalog R}}.  


The Type 1134-A is an accessory for the Type [[1130-A]] Digital Time and Frequency Meter. It's purpose is to convert digital information for the frequency meter to analog voltage for recorder use. The 1134-A can be used with any device producing digital data at the appropriate logic voltage levels.  The conversion of digital data enables plotting resulting in a permanant record.
It is an accessory for the Type [[1130-A]] Digital Time and Frequency Meter with the purpose to convert the meter's digital readout to analog voltage for a recorder/plotter to create a permanent record.  
The 1134-A can be used with any device producing digital data at the appropriate logic voltage levels.   


==Specifications==
==Specifications==
   
   
* '''Data Input:''' BCD, weighted 1-2-4-2 or 1-2-2-4. Binary "1" +90 V max. Binary "0" +150 V min
* '''Data Input:''' BCD, weighted 1-2-4-2 or 1-2-2-4. Binary "1" +90 V max. Binary "0" +150 V min
* '''Output:''' 1 ma at 30 kΩ  source impedance or 100 mv across 100 Ω. Positive side grounded
* '''Output:''' 1 ma at 30 kΩ  source impedance or 100 mv across 100 Ω, positive side grounded
* '''Load:''' 2000 Ω maximum for 1 mA. 2000 Ω minimum for 100 mV
* '''Load:''' 2 kΩ maximum for 1 mA, 2 kΩ min. for 100 mV


==Links==
==Links==


* [[Media:GR Exp 1134-A 10_1961.pdf|Experimenter describing Type 1134-A October 1961]]
* [[Media:GR Exp 1134-A 10_1961.pdf|Experimenter October 1961 describing Type 1134-A]]
* [[Media:GR Exp 1130-A 05_1961.pdf|Experimenter describing Type GR Exp 1130-A May 1961]]
* [[Media:GR Exp 1130-A 05_1961.pdf|Experimenter describing May 1961 Type GR 1130-A]]
* [[Media:GR 1130A Digital Frequency Meter 1130-0110-A 11_1965.pdf|Type GR 1130A Digital Frequency Meter Manual 1130-0110-A 11_1965]]


==Photos==
==Photos==

Navigation menu