2,366
edits
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{GR Product | {{GR Product | ||
|model=1606-A | |model=1606-A | ||
|codes=CIGAR | |||
|class=impedance measurement | |class=impedance measurement | ||
|summary=RF Bridge | |summary=RF Bridge | ||
Line 15: | Line 16: | ||
The '''General Radio 1606-A RF Bridge''' was introduced in {{Catalog O}} and remained available through {{Catalog S}}. | The '''General Radio 1606-A RF Bridge''' was introduced in {{Catalog O}} and remained available through {{Catalog S}}. | ||
The Type 1606-A is null type instrument for measuring relatively low impedances. | The Type 1606-A is null-type instrument for measuring relatively low impedances. | ||
Its frequency range is 400 kHz to 60 MHz but that can be expanded with reduced accuracy. | |||
Any oscillator delivering 0.1 to 10 V at the frequency of interest can be used as a generator. | |||
The detector often used is a radio receiver of the proper frequency with adjustable gain and AVC. | |||
The recommended detectors are of the heterodyne or DNT type. Applications for the 1606-A include analysis of antennas, components and networks of relatively low impedance. | |||
==Specifications== | ==Specifications== | ||
* '''Frequency Range:''' 400 kHz to 60 MHz | * '''Frequency Range:''' 400 kHz to 60 MHz | ||
* '''Reactance Range''' | * '''Reactance Range''' ±5000 Ω at 1 MHz; range varies inversely with frequency, see manual | ||
* '''Resistance Range:''' 0 to 1000 Ω | * '''Resistance Range:''' 0 to 1000 Ω | ||