The Type 1217-C is general purpose unit type pulse generator. It's an improved version of the Type [[1217-B]] with increased pulse repetition frequency and faster transition times to less than 10 ns. The 1217-C features a 1.2 MHz PRF internally and doubles to 2.4 MHz with external drive. Other features are front panel outputs for positive an negative going pulses with variable amplitude control. Pulse duration is continuously variable from 0.1 μs to 1 s in seven ranges. Front panel synchronizing outputs are available for triggering external devices. An accessory Type [[1217-P2]] Pulse Trigger is available for single pulse triggering. The recommended power supplies are the Types [[1201-C]] and [[1203-B]].
Type 1217-C is a general-purpose [[unit instruments|unit type]] pulse generator, an improved version of Type [[1217-B]] with increased pulse repetition frequency and faster transition times to less than 10 ns.  
 
The 1217-C features a 1.2 MHz PRF internally which doubles to 2.4 MHz with external drive. Other features are front-panel outputs for positive- and negative-going pulses with variable amplitude control.  
 
Pulse duration is continuously variable from 0.1 μs to 1 s in seven ranges. Front panel synchronizing outputs are available for triggering external devices.  
 
The [[1217-P2|1217-P2 Pulse Trigger accessory]] was available for single pulse triggering.  
 
Recommended power supplies are Types [[1201-C]] and [[1203-B]].


==Specifications==
==Specifications==
Line 21: Line 29:
* '''PULSE REPETITION RATE'''
* '''PULSE REPETITION RATE'''
* '''Internally Generated:''' 2.5 Hz to 1.2 MHz, ±5%
* '''Internally Generated:''' 2.5 Hz to 1.2 MHz, ±5%
* '''Externally Controlled:'''  dc to 2.4 MHz with 1 V rms input, (0.5 V at 1 Mc/s and lower)
* '''Externally Controlled:'''  dc to 2.4 MHz with 1 V<sub>RMS</sub> input, (0.5 V at 1 MHz and lower)


* '''OUTPUT PULSE CHARACTERISTICS'''
* '''OUTPUT PULSE CHARACTERISTICS'''
* '''Duration:''' 100 ns to 1 s in 7 decade ranges, ±5% of reading or ±2% of full scale or ±35 ns, whichever is greater.
* '''Duration:''' 100 ns to 1 s in 7 decade ranges, ±5% of reading or ±2% of full scale or ±35 ns, whichever is greater
* '''Rise and Fall Times:''' Less than 10 ns into 50 or 100 Ω; typically 60 ns + 2 ns/pF external load capacitance into 1 kΩ (40 V).