The {{Title|General Radio 1750-A Sweep Drive}} was introduced in {{Catalog O}} and remained available through {{Catalog T}}. | The {{Title|General Radio 1750-A Sweep Drive}} was introduced in {{Catalog O}} and remained available through {{Catalog T}}. | ||
The Type 1750-A sweep drive is designed to mechanically sweep an oscillator through a flexible universal coupling. The sweep action is reciprocating motion of the attached oscillator's frequency control. Front panel controls for sweep arc, sweep speed, manual rotation. The sweep drive provides two synchronized circuits, a horizontal voltage for oscilloscope deflection and a blanking circuit which eliminates the return trace. With the mechanical sweep and the auxiliary circuits | The Type 1750-A sweep drive is designed to mechanically sweep an oscillator through a flexible universal coupling. The sweep action is reciprocating motion of the attached oscillator's frequency control. | ||
Front-panel controls are available for sweep arc, sweep speed, and manual rotation. | |||
The sweep drive provides two synchronized circuits, a horizontal voltage for oscilloscope deflection, and a blanking circuit which eliminates the return trace. | |||
With the mechanical sweep and the auxiliary circuits, an oscilloscope display is possible. | |||
For every cycle of the oscillator sweep, a blanking signal and horizontal deflection voltage are created. | |||
The blanking signal is produced by a synchronized, cam-operated blanking switch. | |||
The synchronized oscilloscope horizontal voltage is produced by the oscilloscope deflection rheostat. | |||
A set of limit switches are designed to stop the sweep motor if the limits are exceeded. One limit is fixed, the other is adjustable. | |||
A system comprising the 1750-A sweep drive, an oscillator, and oscilloscope are used to create a spectrum display for the device of interest. The device can be a filter, amplifier, network or radio receiver. | A system comprising the 1750-A sweep drive, an oscillator, and oscilloscope are used to create a spectrum display for the device of interest. The device can be a filter, amplifier, network or radio receiver. | ||
Not all oscillators are compatible with the 1750-A, check | Not all oscillators are compatible with the 1750-A, check the oscillator manual for compatibility. | ||
==Specifications== | ==Specifications== | ||
Line 38: | Line 44: | ||
* '''Sweep Voltage:''' 2.5 V peak to peak, ungrounded | * '''Sweep Voltage:''' 2.5 V peak to peak, ungrounded | ||
* '''Blanking:''' shorting contact closed during clockwise rotation of driven shaft; ungrounded | * '''Blanking:''' shorting contact closed during clockwise rotation of driven shaft; ungrounded | ||