783-A: Difference between revisions

no edit summary
No edit summary
No edit summary
Line 1: Line 1:
[[File:GR 783-A Front.jpg|thumb|450px|right|General Radio 783A Output-Power Meter]]
{{GR Product
The '''General Radio 783A''' is an Output-Power Meter [[introduced in 1944]] Catalog K3 and remained available through Catalog Q 1961.  
|model=783-A
|class=power measurement
|summary=output-power meter
|image=GR 783-A Front.jpg
|caption=General Radio 783A Output-Power Meter
|series=
|introduced=1944
|discontinued=1961
|designers=
|manuals=
* [[Media:GR 783A Output-Power Meter 548 1960.pdf|General Radio 783A Output-Power Meter Manual 548F (1967)]] (OCRed)
}}
The '''General Radio 783A''' is an Output-Power Meter [[introduced in 1944|introduced in 1944 Catalog K3]].  It remained available through Catalog Q 1961.  
 
The 783-A is acts as an adjustable load impedance, with a voltmeter calibrated directly in watts dissipated in the load.   
The 783-A is acts as an adjustable load impedance, with a voltmeter calibrated directly in watts dissipated in the load.   
It can safely handle 100 W at audio frequencies.   
It can safely handle 100 W at audio frequencies.   
It can be used to test amplifiers, transformers, oscillators, filters, and similar networks.  
It can be used to test amplifiers, transformers, oscillators, filters, and similar networks.  


CAUTION: This device contains asbestos.


:'''''CAUTION: This device contains asbestos.'''''


==Specifications==
==Specifications==
Line 12: Line 25:
* '''Impedance Range:''' 2.5 to 20,000 Ω.
* '''Impedance Range:''' 2.5 to 20,000 Ω.
* '''Power Accuracy:''' ±0.25 dB at full-scale reading. Overall frequency characteristic of power indication is flat within ±0.5 dB from 20 to 10,000 Hz; within 0.75 dB to 15,000 Hz.
* '''Power Accuracy:''' ±0.25 dB at full-scale reading. Overall frequency characteristic of power indication is flat within ±0.5 dB from 20 to 10,000 Hz; within 0.75 dB to 15,000 Hz.
==Manuals==
* [[Media:GR 783A Output-Power Meter 548 1960.pdf|General Radio 783A Output-Power Meter Manual 548F (1967)]] (OCRed)


==Links==
==Links==