1216-A

Revision as of 03:26, 3 April 2024 by Jerry (talk | contribs)

The General Radio 1216-A Unit IF Amplifier and DNT Detector was introduced in 1954 Catalog N and remained available through Catalog T 1968.

General Radio 1216-A
Unit if amplifier and dnt detector
General Radio 1216-A Unit IF Amplifier and DNT Detector

Available from 1954 to 1968

Manuals
Catalog History
 Document Year Page
Catalog N 1954 118
Catalog O 1956 68
Catalog P 1959 66
Catalog Q 1961 58
Catalog R 1963 82
Catalog S 1965 107
Catalog T 1968 122
(All manuals in PDF format unless noted otherwise)

Specifications

  • Center Frequency: 30 MHz
  • Bandwidth: 0.7 MHz at 3 dB down; 9.5 MHz at 60 dB down
  • Attenuator Range: 0 to 70 dB in 10 dB steps, a single 3 dB step is also provided
  • Sensitivity: Less than 2 μV input from a 400 Ω source required for a 1% meter deflection (above noise). Less than 50 μV input from a 400 Ω source required for full-scale meter deflection. Input voltages referred to are open circuit source voltages.