The {{Title|General Radio 1401-D Standard Air Capacitor}} was introduced in {{Catalog N}} and remained available through {{Catalog S}}. | The {{Title|General Radio 1401-D Standard Air Capacitor}} was introduced in {{Catalog N}} and remained available through {{Catalog S}}. | ||
The Type 1401-D is 1000 pF two terminal air capacitor designed as a laboratory reference or working capacitance standard. It features all aluminum construction with shielded cover. Connections are Type 274 plugs spaced ¾ inches on center. This spacing matches the Type [[716-C]] making them useful as balancing capacitors when performing substitution measurements. The Type 1401-D is one of four in the series. For an overview of these capacitors see Type [[1401]] Series. | The Type 1401-D is 1000 pF two terminal air capacitor designed as a laboratory reference or working capacitance standard. It features all aluminum construction with shielded cover. Connections are Type 274 plugs spaced ¾ inches on center. This spacing matches the Type [[716-C]] making them useful as balancing capacitors when performing substitution measurements. The Type 1401-D is one of four in the series. | ||
For an overview of these capacitors see Type [[1401]] Series. | |||
==Specifications== | ==Specifications== |
Revision as of 03:07, 11 May 2024
The General Radio 1401-D Standard Air Capacitor was introduced in Catalog N (1954) and remained available through Catalog S (1965).
The Type 1401-D is 1000 pF two terminal air capacitor designed as a laboratory reference or working capacitance standard. It features all aluminum construction with shielded cover. Connections are Type 274 plugs spaced ¾ inches on center. This spacing matches the Type 716-C making them useful as balancing capacitors when performing substitution measurements. The Type 1401-D is one of four in the series.
For an overview of these capacitors see Type 1401 Series.
Specifications
- Insertion Capacitance: 1000 pF
- Initial Accuracy: 0.1%
- Peak Voltage: 700 V
- Dissipation Factor: 0.00001