Accessory filters [[1231-P2]] 60 Hz, [[1231-P3]] 400 and 1000 Hz are available to tune the amplifier to those frequencies. The Type [[1231-P5]] variable filter covers 50 Hz to 100 kHz.  To adapt the 1231-B for use with a slotted line the Type [[1231-P4]] adjustable attenuator is used for standing-wave ratio measurements.  Caution: When using the [[1261-A]] power supply the 1231-A must be switched on and an external switch controlling the power supply.  
Accessory filters [[1231-P2]] 60 Hz, [[1231-P3]] 400 and 1000 Hz are available to tune the amplifier to those frequencies. The Type [[1231-P5]] variable filter covers 50 Hz to 100 kHz.  To adapt the 1231-B for use with a slotted line the Type [[1231-P4]] adjustable attenuator is used for standing-wave ratio measurements.  Caution: When using the [[1261-A]] power supply, the 1231-A must be switched on and an external switch must be used to control the power supply.  


==Specifications==
==Specifications==

Revision as of 00:08, 9 May 2024

General Radio 1231-B
Amplifier and Null Detector
General Radio 1231-B Amplifier and Null Detector

Available from 1948 to 1959

Manuals
Catalog History
 Document Year Page
(All manuals in PDF format unless noted otherwise)

The General Radio 1231-B Amplifier and Null Detector was introduced in Catalog L (1948) and remained available through Catalog P (1959).

The Type 1231-B is a combination three stage hi-gain amplifier and dual range null detector. The first stage of the amplifier uses a two step attenuator, the second stage introduces variable gain control, finally the third stage applies tuning filters and amplification. The null detector or voltmeter has two ranges using push-buttons or can be disabled. The panel meter has two scales, voltage and decibels along with a battery check function. The 1231-B is designed for battery operation or AC operation using the Type 1261-A power supply. Regardless of power supply used the amplifier bias supply is provided by "Bias Cells".

A front panel phone jack is available for filters to apply to the amplifier. Accessory filters 1231-P2 60 Hz, 1231-P3 400 and 1000 Hz are available to tune the amplifier to those frequencies. The Type 1231-P5 variable filter covers 50 Hz to 100 kHz. To adapt the 1231-B for use with a slotted line the Type 1231-P4 adjustable attenuator is used for standing-wave ratio measurements. Caution: When using the 1261-A power supply, the 1231-A must be switched on and an external switch must be used to control the power supply.

Specifications

  • Input Impedance: 1 MΩ in parallel with 20 pF; alternate 10 MΩ input available
  • Maximum Gain: Greater than 83 dB at 1 kHz with 1 MΩ load
  • Null Detector Sensitivity: Less than 25 μV input gives 1% indication on meter at 1 kHz
  • Output Impedance: Approximately 50 kΩ
  • Maximum Output Voltage: 5 volts into 20 kΩ; 20 V into 1 MΩ