1611-B: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 13: Line 13:
{{Catalog History}}
{{Catalog History}}
}}
}}
The '''General Radio 1611-B Capacitance Test Bridge''' was introduced in {{Catalog P}} and remained available through {{Catalog S}}.  
The {{Title|General Radio 1611-B Capacitance Test Bridge}}} was introduced in {{Catalog P}} and remained available through {{Catalog S}}.  


The Type 1611-B self contained capacitance bridge operating at 60 Hz. It can be used at 120 Hz with an external oscillator and filter, the Type [[1214-D]] is recommended. Capacitance measurements at 120 cps are used primarily for the measurement of polarized electrolytic capacitors. A 6E5 "Eye" tube is used as the null indicator along with a detector sensitivity control.  The bridge is suitable for testing of paper, mica, and electrolytic capacitors with 1% accuracy.
The Type 1611-B self contained capacitance bridge operating at 60 Hz. It can be used at 120 Hz with an external oscillator and filter, the Type [[1214-D]] is recommended. Capacitance measurements at 120 cps are used primarily for the measurement of polarized electrolytic capacitors. A 6E5 "Eye" tube is used as the null indicator along with a detector sensitivity control.  The bridge is suitable for testing of paper, mica, and electrolytic capacitors with 1% accuracy.
Line 19: Line 19:
==Specifications==
==Specifications==
   
   
* '''Capacitance Range:''' 0 to 11,000 μF in eight ranges
* '''Capacitance Range:''' 0 to 11,000 μF in eight ranges
* '''Test-Voltage Frequency:''' 60 Hz with internal supply and filter; 120 cps with external supply on four higher multipliers
* '''Test-Voltage Frequency:''' 60 Hz with internal supply and filter; 120 Hz with external supply on four higher multipliers
* '''Capacitance Accuracy:''' ±(1% + l μμF) over the entire range
* '''Capacitance Accuracy:''' ±(1% + l pF) over the entire range
* '''Dissipation-Factor Range:''' 0 to 60% at 60 cps (x f/60 at other frequencies)
* '''Dissipation-Factor Range:''' 0 to 60% at 60 Hz (x f/60 at other frequencies)
* '''Dissipation-Factor Accuracy:''' ±(2% of dial reading + 0.05% x f/60 dissipation factor)
* '''Dissipation-Factor Accuracy:''' ±(2% of dial reading + 0.05% x f/60 dissipation factor)



Revision as of 20:04, 20 April 2024

General Radio 1611-B
Capacitance Test Bridge
General Radio 1611-B Capacitance Test Bridge

Available from 1959 to 1965

Manuals
Catalog History
 Document Year Page
Catalog P 1959 18
Catalog Q 1961 10
Catalog R 1963 42
Catalog S 1965 67
(All manuals in PDF format unless noted otherwise)

The General Radio 1611-B Capacitance Test Bridge} was introduced in Catalog P (1959) and remained available through Catalog S (1965).

The Type 1611-B self contained capacitance bridge operating at 60 Hz. It can be used at 120 Hz with an external oscillator and filter, the Type 1214-D is recommended. Capacitance measurements at 120 cps are used primarily for the measurement of polarized electrolytic capacitors. A 6E5 "Eye" tube is used as the null indicator along with a detector sensitivity control. The bridge is suitable for testing of paper, mica, and electrolytic capacitors with 1% accuracy.

Specifications

  • Capacitance Range: 0 to 11,000 μF in eight ranges
  • Test-Voltage Frequency: 60 Hz with internal supply and filter; 120 Hz with external supply on four higher multipliers
  • Capacitance Accuracy: ±(1% + l pF) over the entire range
  • Dissipation-Factor Range: 0 to 60% at 60 Hz (x f/60 at other frequencies)
  • Dissipation-Factor Accuracy: ±(2% of dial reading + 0.05% x f/60 dissipation factor)