The '''General Radio 1001-A''' is a standard signal generator introduced in 1951 Catalog M and remained available through Catalog 1973.
The '''General Radio 1001-A''' is a standard signal generator introduced in {{Catalog M}}.  It remained available through {{Catalog 1973}}.


The 1001-A covers a frequency range of 5 kHz to 50 MHz. It has a calibrated attenuator with output 0.1 μV to 200 mV and also 2 V direct output. The internal RF oscillator and turret band switch are removable for servicing. Inside the cabinet is a hex alignment tool for adjusting the oscillator turret coils.
The 1001-A covers a frequency range of 5 kHz to 50 MHz. It has a calibrated attenuator with output 0.1 μV to 200 mV and also 2 V direct output. The internal RF oscillator and turret band switch are removable for servicing. Inside the cabinet is a hex alignment tool for adjusting the oscillator turret coils.

Revision as of 19:20, 2 April 2024

General Radio 1001-A
standard signal generator
General Radio 1001-A Signal Generator

Available from 1951 to 1973

Manuals
(All manuals in PDF format unless noted otherwise)

The General Radio 1001-A is a standard signal generator introduced in Catalog M (1951). It remained available through Catalog 1973.

The 1001-A covers a frequency range of 5 kHz to 50 MHz. It has a calibrated attenuator with output 0.1 μV to 200 mV and also 2 V direct output. The internal RF oscillator and turret band switch are removable for servicing. Inside the cabinet is a hex alignment tool for adjusting the oscillator turret coils.

Specifications

  • Frequency Range: 5 kHz to 50 MHz in 8 bands.
  • Accuracy: ±1% of reading.
  • Stability: Warmup drift is in the order of 0.25%. Half the maximum drift is reached in approximately 1½ hours.
  • Amplitude Modulation: 0 to 80%, continuously variable, indicated on the panel meter to ±10% of reading.
  • Modulation Frequency: 400 Hz internal, 20 Hz to 15 kHz external modulation.
  • Output Impedance: 10 Ω except the 100 mV multiplier setting 50 Ω, 300 Ω at the 2 V output.


Links