1808: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 11: Line 11:
* [[Media:GRwiki 1808 AC Milivoltmeter 8608-0100-A 1970.pdf|General Radio 1808 AC Millivoltmeter 1808-0100-A 1970]]
* [[Media:GRwiki 1808 AC Milivoltmeter 8608-0100-A 1970.pdf|General Radio 1808 AC Millivoltmeter 1808-0100-A 1970]]
}}
}}
The '''General Radio ''' was only available in Catalog U 1970.  
The '''General Radio 1808 AC Millivoltmeter''' was only available in Catalog U 1970.  


The Type 1808 is a solid state average-reading voltmeter calibrated to read the rms value
The Type 1808 is a solid state average-reading voltmeter calibrated to read the RMS value
of sine waves.  It has frequency response from 10 Hz to 10 Mhz and six ranges at 20 dB intervals and a DC output function.  The DC function can be used to drive a recorder.
of sine waves.  It has frequency response from 10 Hz to 10 MHz, six ranges at 20 dB intervals, and a DC output that can be used to drive a recorder.


==Specifications==
==Specifications==
   
   
* '''Range:''' 150 mV to 150 V rms in six 20-dB ranges.
* '''Range:''' 150 mV<sub>RMS</sub> to 150 V<sub>RMS</sub> in six 20-dB ranges
* '''Input Impedance:''' 10 MΩ at 1O pF except 12.5 MΩ on 15 V and 150V ranges.
* '''Input Impedance:''' 10 MΩ at 1O pF except 12.5 MΩ on 15 V and 150 V ranges
* '''Accuracy:''' 1% basic accuracy.
* '''Accuracy:''' 1% basic accuracy
* '''Bandwidth:''' 10 Hz to 10 MHz.
* '''Bandwidth:''' 10 Hz to 10 MHz


==Links==
==Links==

Revision as of 05:59, 2 April 2024

General Radio 1808
ac millivoltmeter
General Radio 1808 AC Millivoltmeter

Available from 1970 to 1970

Manuals
(All manuals in PDF format unless noted otherwise)

The General Radio 1808 AC Millivoltmeter was only available in Catalog U 1970.

The Type 1808 is a solid state average-reading voltmeter calibrated to read the RMS value of sine waves. It has frequency response from 10 Hz to 10 MHz, six ranges at 20 dB intervals, and a DC output that can be used to drive a recorder.

Specifications

  • Range: 150 mVRMS to 150 VRMS in six 20-dB ranges
  • Input Impedance: 10 MΩ at 1O pF except 12.5 MΩ on 15 V and 150 V ranges
  • Accuracy: 1% basic accuracy
  • Bandwidth: 10 Hz to 10 MHz

Links

Photos