1140-A: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{GR Product | {{GR Product | ||
|model=1140-A | |model=1140-A | ||
|codewords=WAGER | |||
|class=frequency standards and meters | |class=frequency standards and meters | ||
|summary=UHF Wavemeter | |summary=UHF Wavemeter | ||
Line 21: | Line 22: | ||
==Specifications== | ==Specifications== | ||
* '''Frequency Range:''' 240-1200 MHz in one range | * '''Frequency Range:''' 240-1200 MHz in one range | ||
* '''Accuracy:''' ±2% of the indicated frequency | * '''Accuracy:''' ±2% of the indicated frequency | ||
* '''Detector:''' A type 1N22 Crystal Detector (Microwave Diode) | * '''Detector:''' A type 1N22 Crystal Detector (Microwave Diode) | ||
==Links== | ==Links== |
Revision as of 05:19, 30 March 2024
The General Radio 1140-A UHF Wavemeter introduced in 1948 Catalog L and remained available through Catalog N 1954.
The 1140-A is a simple device to measure frequency in the UHF range of 240 to 1200 MHz with 2% accuracy. Behind the rear window is what's called a Butterfly circuit which varies capacitance and inductance simultaneously to atain resonance. Resonance is indicated with a micro ammeter.
Specifications
- Frequency Range: 240-1200 MHz in one range
- Accuracy: ±2% of the indicated frequency
- Detector: A type 1N22 Crystal Detector (Microwave Diode)