The General Radio 1396-A Tone-Burst Generator was available in 1968 Catalog T only.
Specifications
- Signal to be gated:
- Frequency Range: dc to 500 kHz.
- Maximum Voltage Level: ±7 V (5 V, rms).
- Input Impedance: Approximately 10 kΩ.
- Timing Signal:
- Frequency Range: dc to 500 kHz.
- Maximum Voltage Level: ±10 V.
- Minimum Valtage Level: 1 V, p-to-p.
- Input Impedance: Approximately 7 kΩ.
- Triggering: Slope selectable, trigger level adjustable from -7 to +7 V.
- Gated Signal Output:
- Gate Open Output: Maximum signal level is ±7 V.
- Gate-Closed Output: Less than 140 mV, p-to-p, (-40 dB) with maximum signal input.