* [[Media:GR 1156A PreScaler No OCR.pdf|General Radio 1156-A Decade Scaler 1156-0100-A 1966 (Needs OCR)]]
* [[Media:GR 1156A PreScaler No OCR.pdf|General Radio 1156-A Decade Scaler 1156-0100-A 1966 (Needs OCR)]]
}}
}}
The '''General Radio 1156-A Decade Scaler''' introduced in 1965 Catalog S and remained available through Catalog T 1968. The 1156-A is a 10 to 1 divider used to pre scale the input signal to a frequency meter or counter.  Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument.  Included are covers for the relocated connector holes to make a clean installation.   
The '''General Radio 1156-A Decade Scaler''' introduced in 1965 Catalog S and remained available through Catalog T 1968.  
 
The 1156-A is a 10 to 1 divider used to pre scale the input signal to a frequency meter or counter.  Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument.  Included are covers for the relocated connector holes to make a clean installation.   


==Specifications==
==Specifications==

Revision as of 19:48, 7 March 2024

General Radio 1156-A
decade scaler
General Radio 1156-A Decade Scaler

Available from 1965 to 1968

Manuals
(All manuals in PDF format unless noted otherwise)

The General Radio 1156-A Decade Scaler introduced in 1965 Catalog S and remained available through Catalog T 1968.

The 1156-A is a 10 to 1 divider used to pre scale the input signal to a frequency meter or counter. Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument. Included are covers for the relocated connector holes to make a clean installation.

Specifications

  • Input: DC to 100 MHz.
  • Output: DC to 10 MHz.
  • Sensitivity: 0.1, 0.2, 0.5, and 1 V, p-to-p, at 50 Ω; 1 V, p-to-p, at 500 Ω.
  • Input Impedance: 50 Ω or 500 Ω, sensitivity switch selected.
  • Output Impedance: 250 Ω.