The {{Title|General Radio 1153-A Digital Frequency Meter}}, a general-purpose frequency meter and event counter, was available in {{Catalog S}} only. | The {{Title|General Radio 1153-A Digital Frequency Meter}}, a general-purpose frequency meter and event counter, was available in {{Catalog S}} only. | ||
The display consists of five "Numerik" incandescent readouts (see [[IND-0300]] and [[IND-1801]] for details). | The display consists of five "[[Numerik]]" incandescent readouts (see [[IND-0300]] and [[IND-1801]] for details). | ||
It is interesting to note that if a lamp fails, the counter will stop at that digit because the lamp is part of the counting circuit. | It is interesting to note that if a lamp fails, the counter will stop at that digit because the lamp is part of the counting circuit. | ||
Latest revision as of 15:06, 18 October 2024
The General Radio 1153-A Digital Frequency Meter, a general-purpose frequency meter and event counter, was available in Catalog S (1965) only.
The display consists of five "Numerik" incandescent readouts (see IND-0300 and IND-1801 for details). It is interesting to note that if a lamp fails, the counter will stop at that digit because the lamp is part of the counting circuit.
Specifications
- Frequency Range: DC to 10 MHz
- Calibration Accuracy: ±1 count ± time-base stability
- Sensitivity: 0.1 Vp-p (30 mVRMS) at 100 kΩ and 50 pF; 1.0 Vp-p (0.3 VRMS) at 1 MΩ and 20 pF
Links
- Experimenter September 1965 describing Type 1153-A
- Experimenter August 1964 describing the Numerik Display
Photos
-
-
Note the spare lamps
-
Note the spare lamps
-
-
-