1409-R: Difference between revisions
No edit summary |
No edit summary |
||
Line 16: | Line 16: | ||
The {{Title|General Radio General Radio 1409-R Standard Capacitor}} was introduced in {{Catalog O}} and remained available through {{Catalog U}}. | The {{Title|General Radio General Radio 1409-R Standard Capacitor}} was introduced in {{Catalog O}} and remained available through {{Catalog U}}. | ||
The 1409-R is a fixed mica capacitor of very high stability for use as two or three-terminal capacitance | The 1409-R is a fixed mica capacitor of very high stability for use as two- or three-terminal capacitance standard in the laboratory. | ||
The capacitor is installed in an aluminum case along with silica-gel desiccant, then sealed with high-temperature potting wax. | |||
A well located on the right side of the case allows insertion of a dial-type thermometer. | |||
Three jack-top binding posts on the top of the case and removable plugs on the bottom are provided for convenient parallel connection without error. | |||
Each capacitor is supplied with a certificate of calibration giving two- and three-terminal measured capacitance. | |||
The Type 1409-R capacitor is mounted in the small case. | |||
See [[1409]] to view all the capacitors in the series. | See [[1409]] to view all the capacitors in the series. |
Latest revision as of 19:32, 24 June 2024
The General Radio General Radio 1409-R Standard Capacitor was introduced in Catalog O (1956) and remained available through Catalog U (1970).
The 1409-R is a fixed mica capacitor of very high stability for use as two- or three-terminal capacitance standard in the laboratory. The capacitor is installed in an aluminum case along with silica-gel desiccant, then sealed with high-temperature potting wax.
A well located on the right side of the case allows insertion of a dial-type thermometer. Three jack-top binding posts on the top of the case and removable plugs on the bottom are provided for convenient parallel connection without error.
Each capacitor is supplied with a certificate of calibration giving two- and three-terminal measured capacitance.
The Type 1409-R capacitor is mounted in the small case.
See 1409 to view all the capacitors in the series.
Specifications
- Capacitance: 0.05 μF
- Series Inductance: 0.055 μH
- Adjustment Accuracy: within ±0.05%
- Stability: Capacitance change is less than 0.01% per year
- Temperature Coefficient: capacitance; +35 ± 10 ppm per degree between 10 °C and 70 °C
- Dissipation Factor: Less than 0.0003 at 1 kHz and 23 °C (see curves). Measured dissipation factor at 1 kHz is stated in the certificate to an accuracy of ±0.00005
- Leakage Resistance: 5000 ohm-farads or 100 GΩ, whichever is the lesser
- Maximum Voltage: 500 V peak below 210 kHz
Links
Photos
-
Change in capacitance as a function of frequency for typical Type 1409 capacitors.
-
Dissipation factor as a function of frequency.
-
Technical Drawing.
-
-
Thermometer Access
-
-
-
-