The {{Title|General Radio 1263-A Amplitude-Regulating Power Supply}} | The {{Title|General Radio 1263-A Amplitude-Regulating Power Supply}} was introduced in {{Catalog O}} and remained available through {{Catalog P}}. | ||
The Type 1263-A is a power supply designed to maintain the output level of an the attached oscillator. Although compatible with most unit oscillators any oscillator with similar power requirements can be used. The 1263-A performs this by monitoring the RF output then adjusting the oscillator's plate supply to maintain a constant amplitude. A two pin Jones modulation connector is provided for unit oscillators requiring it for RF control. A Jones to phone jack adapter cable is required for those unit oscillators. RF monitoring is accomplished with the Type [[874-VR]] Voltmeter Rectifier connection. Front panel blanking connections are provided for sweep operation using Type [[1750-A]]. | The Type 1263-A is a power supply designed to maintain the output level of an the attached oscillator. Although compatible with most unit oscillators any oscillator with similar power requirements can be used. The 1263-A performs this by monitoring the RF output then adjusting the oscillator's plate supply to maintain a constant amplitude. A two pin Jones modulation connector is provided for unit oscillators requiring it for RF control. A Jones to phone jack adapter cable is required for those unit oscillators. RF monitoring is accomplished with the Type [[874-VR]] Voltmeter Rectifier connection. Front panel blanking connections are provided for sweep operation using Type [[1750-A]]. |
Revision as of 21:26, 23 May 2024
The General Radio 1263-A Amplitude-Regulating Power Supply was introduced in Catalog O (1956) and remained available through Catalog P (1959).
The Type 1263-A is a power supply designed to maintain the output level of an the attached oscillator. Although compatible with most unit oscillators any oscillator with similar power requirements can be used. The 1263-A performs this by monitoring the RF output then adjusting the oscillator's plate supply to maintain a constant amplitude. A two pin Jones modulation connector is provided for unit oscillators requiring it for RF control. A Jones to phone jack adapter cable is required for those unit oscillators. RF monitoring is accomplished with the Type 874-VR Voltmeter Rectifier connection. Front panel blanking connections are provided for sweep operation using Type 1750-A.
The 1263-A paired with the 1750-A and unit oscillator of interest are used to create a oscilloscope display for the device under test.
Specifications
- Output Plate Supply: 250 V at 25 mA
- Output Heater Supply; 6 V dc at 500 mA
- RF output regulation: output 0.2 to 2 V with 2% accuracy
- Response time: 3 mA per 3 ms output correction rate