1822: Difference between revisions
Line 55: | Line 55: | ||
<gallery> | <gallery> | ||
GR 1822-2720 Component.jpg|1822-2720 | GR 1822-2720 Component.jpg|1822-2720 | ||
GR 1822-2720 Foil.jpg|1822-2720 | GR 1822-2720 Foil.jpg|1822-2720 | ||
GR 1822-2731 Component.jpg|1822-2731 | GR 1822-2731 Component.jpg|1822-2731 | ||
GR 1822-2731 Foil.jpg|1822-2731 | GR 1822-2731 Foil.jpg|1822-2731 | ||
GR 1822-4750 Component.jpg | GR 1822-4750 Component.jpg|1822-4750 | ||
GR 1822-4750 Foil.jpg | GR 1822-4750 Foil.jpg|1822-4750 | ||
GR 1822-4756 Component.jpg | GR 1822-4756 Component.jpg|1822-4756 | ||
GR 1822-4756 Foil.jpg | GR 1822-4756 Foil.jpg|1822-4756 | ||
GR 1822-4761 Component.jpg | GR 1822-4761 Component.jpg|1822-4761 | ||
GR 1822-4761 Foil.jpg | GR 1822-4761 Foil.jpg|1822-4761 | ||
GR 1822-4766 Component.jpg | GR 1822-4766 Component.jpg|1822-4766 | ||
GR 1822-4766 Foil.jpg | GR 1822-4766 Foil.jpg|1822-4766 | ||
GR 1822-4770 Component.jpg | GR 1822-4770 Component.jpg|1822-4770 | ||
GR 1822-4770 Foil.jpg | GR 1822-4770 Foil.jpg|1822-4770 | ||
GR 1822-4776 Component.jpg | GR 1822-4776 Component.jpg|1822-4776 | ||
GR 1822-4776 Foil.jpg | GR 1822-4776 Foil.jpg|1822-4776 | ||
GR 1822-4780 Component.jpg | GR 1822-4780 Component.jpg|1822-4780 | ||
GR 1822-4780 Foil.jpg | GR 1822-4780 Foil.jpg|1822-4780 | ||
GR 1822-4785 Component.jpg | GR 1822-4785 Component.jpg|1822-4785 | ||
GR 1822-4785 Foil.jpg | GR 1822-4785 Foil.jpg|1822-4785 | ||
GR 1822-4790 Component.jpg | GR 1822-4790 Component.jpg|1822-4790 | ||
GR 1822-4790 Foil.jpg | GR 1822-4790 Foil.jpg|1822-4790 | ||
GR 1822-4796 Component.jpg | GR 1822-4796 Component.jpg|1822-4796 | ||
GR 1822-4796 Foil.jpg | GR 1822-4796 Foil.jpg|1822-4796 | ||
</gallery> | </gallery> | ||
Revision as of 20:59, 22 May 2024
The General Radio 1822 Digital Voltmeter Calibrator was available in Catalog U (1970) only.
The Type 1822 is designed to produce accurate voltages for the testing and calibration of digital voltmeters. It can be used as a precise voltage reference from 100 μV dc to 1111.1 V dc for laboratory use. The output voltage can set to any value with five digit resolution, the resolution is adjustable. The output voltage is displayed using a mechanical digital display with automatic units and decimal placement. External programming is available through a rear panel connector along with an internal automatic step function. Other features include an interference voltage function, polarity reversal, and adjustable output impedance.
Specifications
- Output Voltage: 100 μV dc to 1111.1 V dc in 7 decade ranges
- Output Impedance: <0.5 Ω on 1 V through 1 kV ranges; 200 Ω on 1 mV through 100 mV ranges; A l kΩ, 10 kΩ, or 100 kΩ output resistor can be added to above impedances by front-panel selector switch
- Output Current: 10 mA at full range on 1, 10, and 100-V ranges; 1 mA on 1 kV range
- Accuracy: ±(30 ppm of voltage + 10 ppm of full range + 3 μV) on all ranges except ±(50 ppm of voltage + 10 ppm of full range) on 1-kV range; Accuracy of rear-panel voltages ≤111 mV, ±(30 ppm of voltage + 10 ppm of range +0.5 μV)
Links
Photos
Circuit Boards
-
1822-2720
-
1822-2720
-
1822-2731
-
1822-2731
-
1822-4750
-
1822-4750
-
1822-4756
-
1822-4756
-
1822-4761
-
1822-4761
-
1822-4766
-
1822-4766
-
1822-4770
-
1822-4770
-
1822-4776
-
1822-4776
-
1822-4780
-
1822-4780
-
1822-4785
-
1822-4785
-
1822-4790
-
1822-4790
-
1822-4796
-
1822-4796