907-R144: Difference between revisions
No edit summary |
No edit summary |
||
Line 15: | Line 15: | ||
The {{Title|General Radio 907-R144 Synchronous Dial Drive}} was introduced in {{Catalog O}} and remained available through {{Catalog S}}. | The {{Title|General Radio 907-R144 Synchronous Dial Drive}} was introduced in {{Catalog O}} and remained available through {{Catalog S}}. | ||
The Type 907-R144 is a synchronous dial drive with a pinion speed of 4 rpm. Its function is to sweep the dial of the attached instrument at a rate synchronous with a graphic recorder. For X-Y recorder operation an internal 20 kΩ potentiometer (simultaneously sweep) is used for synchronization. The 907-R144 is self reversing when it encounters a mechanical stop. Functions include plotting frequency versus amplitude. Because of the slow 4 rpm pinion speed the Type 907-R144 is not recommended for oscilloscope presentation and not compatible with 908 dials. | The Type 907-R144 is a synchronous dial drive with a pinion speed of 4 rpm. Its function is to sweep the dial of the attached instrument at a rate synchronous with a graphic recorder. For X-Y recorder operation, an internal 20 kΩ potentiometer (simultaneously sweep) is used for synchronization. The 907-R144 is self-reversing when it encounters a mechanical stop. Functions include plotting frequency versus amplitude. Because of the slow 4 rpm pinion speed, the Type 907-R144 is not recommended for oscilloscope presentation and not compatible with 908 dials. | ||
Compatible oscillators are [[1210-C]], [[1360-B]], [[1361-A]], and [[1564-A]]. | Compatible oscillators are [[1210-C]], [[1360-B]], [[1361-A]], and [[1564-A]]. | ||
Line 23: | Line 23: | ||
* '''Drive Speed:''' 4 RPM | * '''Drive Speed:''' 4 RPM | ||
* '''907 Dial Speed:''' 144° per minuite | * '''907 Dial Speed:''' 144° per minuite | ||
==Links== | ==Links== |
Revision as of 22:20, 5 May 2024
The General Radio 907-R144 Synchronous Dial Drive was introduced in Catalog O (1956) and remained available through Catalog S (1965).
The Type 907-R144 is a synchronous dial drive with a pinion speed of 4 rpm. Its function is to sweep the dial of the attached instrument at a rate synchronous with a graphic recorder. For X-Y recorder operation, an internal 20 kΩ potentiometer (simultaneously sweep) is used for synchronization. The 907-R144 is self-reversing when it encounters a mechanical stop. Functions include plotting frequency versus amplitude. Because of the slow 4 rpm pinion speed, the Type 907-R144 is not recommended for oscilloscope presentation and not compatible with 908 dials.
Compatible oscillators are 1210-C, 1360-B, 1361-A, and 1564-A.
Specifications
- Drive Speed: 4 RPM
- 907 Dial Speed: 144° per minuite
Links
- Experimenter October 1956 describing Synchronous Dial Drives
- Experimenter December 1956 describing X-Y Plotting Sweep Drives