1156-A: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 18: Line 18:


==Specifications==
==Specifications==
* '''Input:''' DC to 100 MHz.
* '''Input:''' DC to 100 MHz
* '''Output:''' DC to 10 MHz.
* '''Output:''' DC to 10 MHz
* '''Sensitivity:''' 0.1, 0.2, 0.5, and 1 V, p-to-p, at 50 Ω; 1 V, p-to-p, at 500 Ω.
* '''Sensitivity:''' 0.1, 0.2, 0.5, and 1 V<sub>p-p</sub> at 50 Ω; 1 V<sub>p-p</sub> at 500 Ω
* '''Input Impedance:''' 50 Ω or 500 Ω, sensitivity switch selected.
* '''Input Impedance:''' 50 Ω or 500 Ω, switch-selected
* '''Output Impedance:''' 250 Ω.
* '''Output Impedance:''' 250 Ω


==Links==
==Links==

Revision as of 02:10, 4 April 2024

General Radio 1156-A
decade scaler
General Radio 1156-A Decade Scaler

Available from 1965 to 1968

Manuals
Catalog History
 Document Year Page
Catalog S 1965 125
Catalog T 1968 178
(All manuals in PDF format unless noted otherwise)

The General Radio 1156-A Decade Scaler introduced in Catalog S (1965) and remained available through Catalog T (1968).

The 1156-A is a 10 to 1 divider used to pre scale the input signal to a frequency meter or counter. Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument. Included are covers for the relocated connector holes to make a clean installation.

Specifications

  • Input: DC to 100 MHz
  • Output: DC to 10 MHz
  • Sensitivity: 0.1, 0.2, 0.5, and 1 Vp-p at 50 Ω; 1 Vp-p at 500 Ω
  • Input Impedance: 50 Ω or 500 Ω, switch-selected
  • Output Impedance: 250 Ω

Links

Photos