874-VQ: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 19: | Line 19: | ||
It contains a 1N23B diode and a mica capacitor. | It contains a 1N23B diode and a mica capacitor. | ||
The 874-VQL is identical but has locking 874 connectors. | The '''874-VQL''' is identical but has locking 874 connectors. | ||
The 874-VQ is similar to the [[874-VR|874-VR Voltmeter Rectifier]], but omits the latter's 50 Ω series resistor, and includes matching elements to compensate for the discontinuity caused by the diode capacitance. | The 874-VQ is similar to the [[874-VR|874-VR Voltmeter Rectifier]], but omits the latter's 50 Ω series resistor, and includes matching elements to compensate for the discontinuity caused by the diode capacitance. |
Revision as of 06:09, 2 April 2024
The General Radio 874-VQ is a "voltmeter detector" with two GR-874 connectors for the signal, and either a GR-874 or a BNC connector for the rectified output.
It is used in frequency response measurements with a 1750-A Sweep Drive and 1263-A Amplitude Regulating Power Supply. An 874-VI Voltmeter Indicator can be used for calibrated measurements from 0.1 to 2 V.
It contains a 1N23B diode and a mica capacitor.
The 874-VQL is identical but has locking 874 connectors.
The 874-VQ is similar to the 874-VR Voltmeter Rectifier, but omits the latter's 50 Ω series resistor, and includes matching elements to compensate for the discontinuity caused by the diode capacitance.
Key Specifications
- Frequency range: 500 kHz to 2 GHz ("in limited application" up to 7 GHz)
- Maximum input: 2 V
- VSWR: ≤1.1 @ 1 GHz, ≤1.2 @ 2 GHz; rising rapidly above 2.5 GHz
- Resonant frequency: 3.6 GHz
Links
- 874-VQL is the locking version.
- 874-VQ datasheet (1963)
Photos
-
874-VQ, BNC output model
-