716-P4: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{GR Product | {{GR Product | ||
|model=716-P4 | |model=716-P4 | ||
|codewords=BOSOMGUARD,BONUSGUARD | |||
|class=impedance measurement | |class=impedance measurement | ||
|summary=guard circuit | |summary=guard circuit | ||
|image=GR 716-P4 Front Close-up.jpg | |image=GR 716-P4 Front Close-up.jpg | ||
|caption=General Radio 716-P4 Guard Circuit | |caption=General Radio 716-P4 Guard Circuit |
Revision as of 03:34, 30 March 2024
The General Radio 716-P4 Guard Circuit was introduced in 1954 Catalog N and remained available through Catalog S 1965.
The Type 716-P4 is an accessory to the 716-C capacitance bridge. Its designed for measurements were the unknown is located some distance or in a test chamber used to simulate a range environmental factors. By the use of 716-P4 it converts the 716-C into a three terminal bridge using double insulated coaxial cable and separate ground to the unknown. The 716-P4 can then balance out the effects of the leads to the unknown.
Specifications
- Capacitance Range: Designed primarily for use with the xl multiplier ranges of the Type 716-C Capacitance Bridge.
- Frequency Range: Corresponds to that of Type 716-C Capacitance Bridge.
- Guard Balance Capacitor: Any value of capacitance between the guard point and the high measuring terminal up to 1000 pF can be balanced out.