The General Radio 1311-A Audio Oscillator is a transistorized Wien-bridge audio oscillator with transformer output. The switched  
The General Radio 1311-A Audio Oscillator is a transistorized Wien-bridge audio oscillator with transformer output. The switched  
output frequencies correspond to commonly used bridge generator frequencies. A delta frequency control is available on the front panel
output frequencies correspond to commonly used bridge generator frequencies. A delta frequency control is available on the front panel
to fine tune the frequency. Although designed as a bridge oscillator its also well suited for audio testing with it low hum and distortion levels.  As a bridge oscillator its part of the [[1660-A]] Inductance and [[1620-A]] Capacitance Measurement Systems.
to fine tune the frequency. Although designed as a bridge oscillator its also well suited for audio testing with its low hum and distortion levels.  As a bridge oscillator its part of the [[1660-A]] Inductance and [[1620-A]] Capacitance Measurement Systems.


==Specifications==
==Specifications==

Revision as of 20:53, 11 March 2024

General Radio 1311-A
audio oscillator
General Radio 1311-A Audio Oscillator

Available from 1963 to 1978+

Manuals
(All manuals in PDF format unless noted otherwise)

The General Radio 1311-A Audio Oscillator was introduced in 1963 Catalog U and remained available through Catalog 1978.

The General Radio 1311-A Audio Oscillator is a transistorized Wien-bridge audio oscillator with transformer output. The switched output frequencies correspond to commonly used bridge generator frequencies. A delta frequency control is available on the front panel to fine tune the frequency. Although designed as a bridge oscillator its also well suited for audio testing with its low hum and distortion levels. As a bridge oscillator its part of the 1660-A Inductance and 1620-A Capacitance Measurement Systems.

Specifications

  • Frequency Range: 11 fixed frequencies – 50, 60, 100, 120, 200, 400, 500, 1000, 2000, 5000, 10,000 Hz selected by rotary switch. A vernier provides a ±2% adjustment about nominal.
  • Power Output: 1 W into matched load. (Taps provide at least 0.5 W output into any resistive load between 80 mΩ and 8 kΩ).
  • Output Voltage: Continuously adjustable from 0 to 1, 3, 10, 30, or 100 V, open circuit.
  • Output Current: Continuously adjustable from 0 to 40, 130, 400, 1300, 4000 mA, short circuit (approx).