Line 14: | Line 14: | ||
The '''General Radio 1632-A Inductance Bridge''' was introduced in 1963 Catalog R and remained available through Catalog 1974. | The '''General Radio 1632-A Inductance Bridge''' was introduced in 1963 Catalog R and remained available through Catalog 1974. | ||
The Type 1632-A inductance bridge is based on the Owen bridge circuit at audio frequencies. The decade controls for "G" and "L" display their values with | The Type 1632-A inductance bridge is based on the Owen bridge circuit at audio frequencies. The decade controls for "G" and "L" display their values with decimals in a series of vertical windows speeding up the measurement. The recommended generator is [[1311-A]] and detector [[1232-A]] which in combination make up the Type [[1660-A]] Inductance Measurement System. | ||
Revision as of 01:14, 11 March 2024
The General Radio 1632-A Inductance Bridge was introduced in 1963 Catalog R and remained available through Catalog 1974.
The Type 1632-A inductance bridge is based on the Owen bridge circuit at audio frequencies. The decade controls for "G" and "L" display their values with decimals in a series of vertical windows speeding up the measurement. The recommended generator is 1311-A and detector 1232-A which in combination make up the Type 1660-A Inductance Measurement System.
Specifications
- Inductance Range: 0.0001 μH to 1111 H.
- Conductance: 0.0001 μ℧ to 1111 ℧.
- Inductance Accuracy: ±0.1%, direct-reading. Accuracy is reduced at the extremes of inductance, Q, and frequency ranges.
- Conductance Accuracy: ±1% direct-reading accuracy. Accuracy is reduced at the extremes of the Land G decades, Q, and frequency.
Links
Photos
-
-
-
-
-
L (Rn) Standards Type 510 Decade Resistance
-
-
-
G (Cn) Standards Type 980 Decade Capacitors