783-A: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
[[File:GR 783-A Front.jpg|thumb|450px|right|General Radio 783A Output-Power Meter]] | [[File:GR 783-A Front.jpg|thumb|450px|right|General Radio 783A Output-Power Meter]] | ||
The '''General Radio 783A''' is an Output-Power Meter [[introduced in 1944]] Catalog K3 and remained available through Catalog Q 1961. | The '''General Radio 783A''' is an Output-Power Meter [[introduced in 1944]] Catalog K3 and remained available through Catalog Q 1961. The 783-A is acts as an adjustable load impedance, with a voltmeter calibrated directly in watts dissipated in the load. It can safely | ||
handle 100 W at audio frequencies. It can be used to test amplifiers, transformers, oscillators, filters, and similar networks. | |||
CAUTION this device contains Asbestos. | |||
==Specifications== | ==Specifications== | ||
Line 21: | Line 25: | ||
GR 783-A Rear Inside.jpg | GR 783-A Rear Inside.jpg | ||
GR 783-A Right Side.jpg | GR 783-A Right Side.jpg | ||
GR 783-A Load Resistors.jpg | GR 783-A Load Resistors.jpg| Asbestos Insulator | ||
GR 783-A Rear.jpg | GR 783-A Rear.jpg | ||
GR 783-A Case.jpg | GR 783-A Case.jpg |
Revision as of 22:20, 22 February 2024
The General Radio 783A is an Output-Power Meter introduced in 1944 Catalog K3 and remained available through Catalog Q 1961. The 783-A is acts as an adjustable load impedance, with a voltmeter calibrated directly in watts dissipated in the load. It can safely handle 100 W at audio frequencies. It can be used to test amplifiers, transformers, oscillators, filters, and similar networks.
CAUTION this device contains Asbestos.
Specifications
- Power Range: 0.2 mW to 100 W in five ranges.
- Impedance Range: 2.5 to 20,000 Ω.
- Power Accuracy: ±O.25 dB at full-scale reading. Over-all frequency characteristic of power indication is flat
within ±O.5 dB from 20 to 10,000 Hz; within 0.75 dB to 15,000 Hz.
Manuals
Links
Photos
-
-
-
-
-
Asbestos Insulator
-
-