874-GA: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 6: Line 6:
|image=GR 874-GA Front A.jpg
|image=GR 874-GA Front A.jpg
|caption=General Radio 874-GA Adjustable Attenuator
|caption=General Radio 874-GA Adjustable Attenuator
|series=874
|series=GR-874
|introduced=1951
|introduced=1951
|discontinued=1961
|discontinued=1961
Line 16: Line 16:
The {{Title|General Radio 874-GA Adjustable Attenuator}} was introduced in {{Catalog M}} and remained available through {{Catalog Q}}.  
The {{Title|General Radio 874-GA Adjustable Attenuator}} was introduced in {{Catalog M}} and remained available through {{Catalog Q}}.  


The Type 874-GA is a mutual-inductance (waveguide-below-cutoff) type attenuator. A micrometer type barrel adjusts the distance between a pick-up loop attached to three foot coaxial cable and the short section of the input coaxial line. Both the barrel and adjusting sleeve are calibrated in decibels, one turn produces a change of 20 dB for a total or 120 dB of attenuation. Used with other coaxial elements the such as [[874-VI]] voltmeter indicator and [[874-VR]] voltmeter rectifier 874-GA can be used to attenuate and monitor signal generators and oscillators. The attenuator can also be used to measure the attenuation of a network by the substitution method.
The Type 874-GA is a mutual-inductance (waveguide-below-cutoff) type attenuator. A micrometer-type barrel adjusts the distance between a pick-up loop attached to a three-foot coaxial cable and the short section of the input coaxial line. Both the barrel and adjusting sleeve are calibrated in decibels, one turn produces a change of 20 dB for a total or 120 dB of attenuation. Used with other coaxial elements the such as the [[874-VI|874-VI Voltmeter Indicator]] or the [[874-VR|874-VR Voltmeter Rectifier]], the 874-GA can be used to attenuate and monitor signal generators and oscillators. The attenuator can also be used to measure the attenuation of a network by the substitution method.


==Specifications==
==Specifications==


* '''Calibrated Range:''' 120 dB
* '''Calibrated Range:''' 120 dB
* '''Accuracy of Attenuation:''' ±0.5 db when corrected
* '''Insertion Loss''':
* '''Frequency Range:''' 100 MHz to 3000 MHz
** At beginning of calibrated range: Approximately inversely proportional to frequency up to 1 GHz; approximately 20 dB at 1 GHz with tuned input; approximately 33 dB with input line terminated in 50 Ω
* '''Waveguide Mode:''' TE 1,1 ; cutoff frequency 12,300 MHz
** Outside of calibrated range: Approximately inversely proportional to frequency; approximately 18 dB at 1 GHz
* '''Accuracy of Attenuation:''' ±0.5 dB when corrected
* '''Frequency Range:''' 100 MHz to 3 GHz
* '''Waveguide Mode:''' TE<sub>1,1</sub>; cutoff frequency 12.3 GHz


==Links==
==Links==

Latest revision as of 23:03, 12 May 2024

General Radio 874-GA
Adjustable Attenuator
General Radio 874-GA Adjustable Attenuator

Available from 1951 to 1961

Manuals
Catalog History
 Document Year Page
Catalog M 1951 121
Catalog N 1954 134
Catalog O 1956 57
Catalog P 1959 54
Catalog Q 1961 48
(All manuals in PDF format unless noted otherwise)

The General Radio 874-GA Adjustable Attenuator was introduced in Catalog M (1951) and remained available through Catalog Q (1961).

The Type 874-GA is a mutual-inductance (waveguide-below-cutoff) type attenuator. A micrometer-type barrel adjusts the distance between a pick-up loop attached to a three-foot coaxial cable and the short section of the input coaxial line. Both the barrel and adjusting sleeve are calibrated in decibels, one turn produces a change of 20 dB for a total or 120 dB of attenuation. Used with other coaxial elements the such as the 874-VI Voltmeter Indicator or the 874-VR Voltmeter Rectifier, the 874-GA can be used to attenuate and monitor signal generators and oscillators. The attenuator can also be used to measure the attenuation of a network by the substitution method.

Specifications

  • Calibrated Range: 120 dB
  • Insertion Loss:
    • At beginning of calibrated range: Approximately inversely proportional to frequency up to 1 GHz; approximately 20 dB at 1 GHz with tuned input; approximately 33 dB with input line terminated in 50 Ω
    • Outside of calibrated range: Approximately inversely proportional to frequency; approximately 18 dB at 1 GHz
  • Accuracy of Attenuation: ±0.5 dB when corrected
  • Frequency Range: 100 MHz to 3 GHz
  • Waveguide Mode: TE1,1; cutoff frequency 12.3 GHz