1134-A: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{GR Product | {{GR Product | ||
|model=1134-A | |model=1134-A | ||
|codes=MOTTO,MINOR | |||
|class=frequency standards and meters | |class=frequency standards and meters | ||
|summary=Analog to digital converter | |summary=Analog to digital converter | ||
Line 22: | Line 23: | ||
* '''Data Input:''' BCD, weighted 1-2-4-2 or 1-2-2-4. Binary "1" +90 V max. Binary "0" +150 V min | * '''Data Input:''' BCD, weighted 1-2-4-2 or 1-2-2-4. Binary "1" +90 V max. Binary "0" +150 V min | ||
* '''Output:''' | * '''Output:''' 1 mA at 30 kΩ source impedance, or 100 mV across 100 Ω, positive side grounded | ||
* '''Load:''' 2 kΩ maximum for 1 mA, 2 kΩ min. for | * '''Load:''' 2 kΩ maximum for 1 mA, 2 kΩ min. for 100mV | ||
==Links== | ==Links== |
Latest revision as of 18:09, 4 May 2024
The General Radio 1134-A Analog to Digital Converter was introduced in Catalog Q (1961) and remained available through Catalog R (1963).
It is an accessory for the Type 1130-A Digital Time and Frequency Meter with the purpose to convert the meter's digital readout to analog voltage for a recorder/plotter to create a permanent record. The 1134-A can be used with any device producing digital data at the appropriate logic voltage levels.
Specifications
- Data Input: BCD, weighted 1-2-4-2 or 1-2-2-4. Binary "1" +90 V max. Binary "0" +150 V min
- Output: 1 mA at 30 kΩ source impedance, or 100 mV across 100 Ω, positive side grounded
- Load: 2 kΩ maximum for 1 mA, 2 kΩ min. for 100mV