716-CS1: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
 
Line 40: Line 40:
GR 716-CSI Rear Lower A.jpg
GR 716-CSI Rear Lower A.jpg
GR 716-CSI Rear Lower.jpg
GR 716-CSI Rear Lower.jpg
GR 716-CS1 Warranty Tag.JPG
</gallery>
</gallery>


[[Category:Impedance measurement]]
[[Category:Impedance measurement]]

Latest revision as of 01:38, 9 May 2024

General Radio 716-CS1
Capacitance bridge
General Radio 716-CS1 Capacitance Bridge

Available from 1954 to 1965

Manuals
Catalog History
 Document Year Page
Catalog N 1954 83
Catalog O 1956 20
Catalog P 1959 12
Catalog Q 1961 33
Catalog R 1963 39
Catalog S 1965 61
(All manuals in PDF format unless noted otherwise)

The General Radio 716-CS1 Capacitance Bridge was introduced in Catalog N (1954) and remained available through Catalog S (1965).

The Type 716-CS1 is a direct-reading capacitance bridge operating at a frequency of 1 MHz. It differs from the 716-C using the 722-N variable capacitor and input transformer both designed to operate at 1 MHz. The 716-CS1 requires a generator and detector operating at 1 MHz, the 1214-M oscillator and 1212-A - 1212-P2 detector-filter combination are recommended. For more information and specifications see the 716-C.

Specifications

  • Capacitance Range: Direct method, 100 to 1100 pF; Substitution method, 0.1 to 1000 pF
  • Dissipation Factor Range: Direct method, 0.00002 to 0.056; Substitution method, see manual
  • Frequency: Direct reading at 1 MHz; 0.5 to 3 MHz with correction
  • Other Specifications: See Type 716-C

Links

Photos