1156-A: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(4 intermediate revisions by one other user not shown) | |||
Line 2: | Line 2: | ||
|model=1156-A | |model=1156-A | ||
|class=frequency standards and meters | |class=frequency standards and meters | ||
|summary= | |summary=Decade scaler | ||
|image=GR 1156-A Front.jpg | |image=GR 1156-A Front.jpg | ||
|caption=General Radio 1156-A Decade Scaler | |caption=General Radio 1156-A Decade Scaler | ||
Line 10: | Line 10: | ||
|designers= | |designers= | ||
|manuals= | |manuals= | ||
* [[Media:GR 1156A PreScaler | * [[Media:GR 1156A PreScaler 1156-0100-A 6_1966.pdf|General Radio 1156-A Decade Scaler Manual 1156-0100-A 1966]] | ||
{{Catalog History}} | {{Catalog History}} | ||
}} | }} | ||
The | The {{Title|General Radio 1156-A Decade Scaler}} was introduced in {{Catalog S}} and remained available through {{Catalog T}}. | ||
The 1156-A is a 10 to 1 divider used to pre scale the input signal to a frequency meter or counter. Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument. Included are covers for the relocated connector holes to make a clean installation. | The 1156-A is a 10 to 1 divider used to pre-scale the input signal to a frequency meter or counter. | ||
Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument. | |||
Included are covers for the relocated connector holes to make a clean installation. | |||
==Specifications== | ==Specifications== |
Latest revision as of 08:04, 15 October 2024
The General Radio 1156-A Decade Scaler was introduced in Catalog S (1965) and remained available through Catalog T (1968).
The 1156-A is a 10 to 1 divider used to pre-scale the input signal to a frequency meter or counter. Pairing the 1156-A to a GR counter is made easier by incorporating input and output connectors that can be relocated to the rear of the instrument. Included are covers for the relocated connector holes to make a clean installation.
Specifications
- Input: DC to 100 MHz
- Output: DC to 10 MHz
- Sensitivity: 0.1, 0.2, 0.5, and 1 Vp-p at 50 Ω; 1 Vp-p at 500 Ω
- Input Impedance: 50 Ω or 500 Ω, switch-selected
- Output Impedance: 250 Ω