1218-B: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(6 intermediate revisions by the same user not shown) | |||
Line 2: | Line 2: | ||
|model=1218-B | |model=1218-B | ||
|class=oscillators | |class=oscillators | ||
|summary= | |summary=Unit oscillator | ||
|image=GR 1218-B Front B.jpg | |image=GR 1218-B Front B.jpg | ||
|caption=General Radio 1218-B Unit Oscillator | |caption=General Radio 1218-B Unit Oscillator | ||
Line 11: | Line 11: | ||
|manuals= | |manuals= | ||
* [[Media:GR 1218B Oscillator 1218-0110-A 1965.pdf|General Radio 1218-B Unit Oscillator Manual 1218-0110-A 1965]] | * [[Media:GR 1218B Oscillator 1218-0110-A 1965.pdf|General Radio 1218-B Unit Oscillator Manual 1218-0110-A 1965]] | ||
{{Catalog History}} | |||
}} | }} | ||
The | The {{Title|General Radio 1218-B Unit Oscillator}} introduced in {{Catalog S}} and remained available through {{Catalog 1978}} in the form of the [[1218-BV]] model. | ||
The 1218-B is an updated version of [[1218-A]] with improved frequency stability, | The 1218-B is an updated version of Type [[1218-A]] with improved frequency stability, and an updated Delta Frequency control for precise frequency adjustment. | ||
Being part of the [[Unit instruments|Unit Oscillator family]], it requires a separate power supply or a modulating power supply. | |||
==Specifications== | ==Specifications== | ||
* '''Frequency Range:''' 900 to 2000 MHz in one range | * '''Frequency Range:''' 900 to 2000 MHz in one range | ||
* '''Frequency Calibration Accuracy:''' ±1% | * '''Frequency Calibration Accuracy:''' ±1% | ||
* '''Warmup Frequency Drift:''' 0.1% approximate total warmup drift | * '''Warmup Frequency Drift:''' 0.1% approximate total warmup drift | ||
* '''Output Power:''' 200 mW into 50 Ω ( | * '''Output Power:''' 200 mW into 50 Ω (see manual) | ||
==Links== | ==Links== |
Latest revision as of 02:45, 16 April 2024
The General Radio 1218-B Unit Oscillator introduced in Catalog S (1965) and remained available through Catalog 1978 in the form of the 1218-BV model.
The 1218-B is an updated version of Type 1218-A with improved frequency stability, and an updated Delta Frequency control for precise frequency adjustment. Being part of the Unit Oscillator family, it requires a separate power supply or a modulating power supply.
Specifications
- Frequency Range: 900 to 2000 MHz in one range
- Frequency Calibration Accuracy: ±1%
- Warmup Frequency Drift: 0.1% approximate total warmup drift
- Output Power: 200 mW into 50 Ω (see manual)