358: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(→Photos) |
||
(7 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{GR Product | {{GR Product | ||
|model=358 | |model=358 | ||
|codes=UPPER | |||
|class=frequency standards and meters | |class=frequency standards and meters | ||
|summary= | |summary=Wavemeter | ||
|image=GR 358 Case Open B.jpg | |image=GR 358 Case Open B.jpg | ||
|caption=General Radio 358 Amateur Band Wavemeter | |caption=General Radio 358 Amateur Band Wavemeter | ||
Line 12: | Line 13: | ||
* '''Manual Needed''' | * '''Manual Needed''' | ||
{{Catalog History}} | {{Catalog History}} | ||
}} | }} | ||
The | The {{Title|General Radio 358 Amateur Band Wavemeter}} was introduced in {{Bulletin 926}} and remained available through {{Catalog K1}}. | ||
The Type 358 is an absorption type wavemeter covering the four overlapping bands. It has | The Type 358 is an absorption-type wavemeter covering the four overlapping bands. It has a frequency accuracy of 1% and uses an incandescent lamp as a resonance indicator. The lamp is in a special socket that closes the connection when the lamp is removed if not needed. | ||
Each wavemeter is supplied with a calibration chart produced with settings accurate for that particular meter. | |||
A [[247|Type 247]] gear-driven condenser is used inside the meter. | |||
==Specifications== | ==Specifications== | ||
Line 52: | Line 46: | ||
GR 358 Wavemeter Inside.jpg | GR 358 Wavemeter Inside.jpg | ||
GR 358 Calibration Chart.png | GR 358 Calibration Chart.png | ||
GR Condenser Brace Top.jpg | |||
GR Condenser Brace Bottom.jpg | |||
GR Condenser Brace Side.jpg | |||
</gallery> | </gallery> | ||
[[Category:Frequency Standards and Meters]] | [[Category:Frequency Standards and Meters]] |
Latest revision as of 00:54, 3 October 2024
The General Radio 358 Amateur Band Wavemeter was introduced in Bulletin 926 (1924) and remained available through Catalog K1 (1939).
The Type 358 is an absorption-type wavemeter covering the four overlapping bands. It has a frequency accuracy of 1% and uses an incandescent lamp as a resonance indicator. The lamp is in a special socket that closes the connection when the lamp is removed if not needed.
Each wavemeter is supplied with a calibration chart produced with settings accurate for that particular meter.
A Type 247 gear-driven condenser is used inside the meter.
Specifications
- Frequency Ranges
- Wavelength: 14 to 28 Meters, 26 to 56 Meters, 54 to 114 Meters, 105 to 220 Meters
- Frequency: 10.0 to 20.0 MHz, 5.0 to 10.0 Mhz, 2.5 to 5.0 MHz, 1.5 to 3.0 MHz
- Accuracy: 1%
Links
- Experimenter describing Type 358 February 1926
- Experimenter describing the calibration of Type 358 July 1927