1654: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(7 intermediate revisions by 2 users not shown) | |||
Line 2: | Line 2: | ||
|model=1654 | |model=1654 | ||
|class=impedance measurement | |class=impedance measurement | ||
|summary= | |summary=Impedance comparator | ||
|image=GR 1654 Front A.jpg | |image=GR 1654 Front A.jpg | ||
|caption=General Radio 1654 Impedance Comparator | |caption=General Radio 1654 Impedance Comparator | ||
Line 11: | Line 11: | ||
|manuals= | |manuals= | ||
* [[Media:GR 1654 Impedance Comparitor 1654-0100-A 1969.pdf|General Radio 1654 Impedance Comparator Manual 1654-0100-A 1969]] | * [[Media:GR 1654 Impedance Comparitor 1654-0100-A 1969.pdf|General Radio 1654 Impedance Comparator Manual 1654-0100-A 1969]] | ||
{{Catalog History}} | |||
}} | }} | ||
The | The {{Title|General Radio 1654 Impedance Comparator}} was introduced in {{Catalog U}} and remained available through {{Catalog 1978}}. | ||
The Type 1654 is third in a line of impedance comparators starting with the [[1604-B]] in 1952 and continued with the [[1605-A]] in 1956. | |||
Like the earlier [[1605-A]], the 1654 was designed for applications of sorting, selecting, and adjusting of components in production and inspection at high speed. | |||
Unlike that predecessor, however, construction is all solid-state, replacing some twenty vacuum tubes. | |||
==Specifications== | ==Specifications== | ||
* '''Impedance Range:''' See | * '''Impedance Range:''' See manual | ||
* '''Frequencies:''' Internal only 100 Hz, 1, 10, and 100 kHz, ±1% | * '''Frequencies:''' Internal only 100 Hz, 1, 10, and 100 kHz, ±1% | ||
* '''Accuracy:''' 3% of full scale | * '''Accuracy:''' 3% of full scale | ||
* '''Resolution:''' Meter, 0.003% and 0.00003 | * '''Resolution:''' Meter, 0.003% and 0.00003 radians; Analog-voltage output, 0.001% and 0.00001 radians | ||
* '''Voltage Across Standard and Unknown:''' 0.3, 1, or 3 V selected by front-panel control | * '''Voltage Across Standard and Unknown:''' 0.3, 1, or 3 V selected by front-panel control | ||
==Links== | ==Links== | ||
* [[Media:GRwiki Exp 1654 05_1969.pdf|Experimenter describing Type 1654 | * [[Media:GRwiki Exp 1654 05_1969.pdf|Experimenter May 1969 describing Type 1654]] | ||
==Photos== | ==Photos== |
Latest revision as of 15:08, 25 April 2024
The General Radio 1654 Impedance Comparator was introduced in Catalog U (1970) and remained available through Catalog 1978.
The Type 1654 is third in a line of impedance comparators starting with the 1604-B in 1952 and continued with the 1605-A in 1956.
Like the earlier 1605-A, the 1654 was designed for applications of sorting, selecting, and adjusting of components in production and inspection at high speed. Unlike that predecessor, however, construction is all solid-state, replacing some twenty vacuum tubes.
Specifications
- Impedance Range: See manual
- Frequencies: Internal only 100 Hz, 1, 10, and 100 kHz, ±1%
- Accuracy: 3% of full scale
- Resolution: Meter, 0.003% and 0.00003 radians; Analog-voltage output, 0.001% and 0.00001 radians
- Voltage Across Standard and Unknown: 0.3, 1, or 3 V selected by front-panel control
Links
Photos
Cards
-
Start-Circuit 1654-4771
-
DC Amplifier 1654-4761
-
Detector Circuit 1654-4741
-
Oscillator Circuit 1654-4711
-
Unbalance Amplifier 1654-4731
-
Extender Card