1150-B: Difference between revisions

From GRWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(5 intermediate revisions by 2 users not shown)
Line 2: Line 2:
|model=1150-B
|model=1150-B
|class=frequency standards and meters
|class=frequency standards and meters
|summary=digital frequency meter
|summary=Digital frequency meter
|image=GR 1150-B Front.jpg
|image=GR 1150-B Front.jpg
|caption=General Radio 1150-B Digital Frequency Meter
|caption=General Radio 1150-B Digital Frequency Meter
Line 11: Line 11:
|manuals=
|manuals=
Manual Needed
Manual Needed
{{Catalog History}}
}}
}}
The '''General Radio 1150-B Digital Frequency Meter''' was only available in Catalog S 1965.  
The {{Title|General Radio 1150-B Digital Frequency Meter}}, a general-purpose frequency meter and event counter, was only available in {{Catalog S}}.
The Type 1150-B is a general purpose frequency meter and event counter. Its an improvment on the 1150-A with  
It is an improvement on the [[1150-A]] with higher frequency range and trigger control.   
higher frequency range and trigger control.  For the frequency display it uses five "Numerik" incadesant readouts.  See [[IND-0300]] also [[IND-1801]] for details. An interesting to note that is a lamp fails the counter will stop at that digit.  The lamp is part of the counting circuit.
 
The display consists of five "Numerik" incandescent readouts (see [[IND-0300]] and [[IND-1801]] for details).
It is interesting to note that if a lamp fails, the counter will stop at that digit because the lamp is part of the counting circuit.


==Specifications==
==Specifications==
* '''Frequency Range"'''' 10 Hz to 400 kHz.
* '''Frequency Range:''' 10 Hz to 400 kHz
* '''Sensitivity''' 0.1 volt, peak-to-peak, at 100 kΩ or 1 volt, peak-to-peak, at 1 MΩ.
* '''Sensitivity''' 0.1 V<sub>p-p</sub> at 100 kΩ or 1 V<sub>p-p</sub> at 1 MΩ
* '''Accuracy:''' ± 1 count ± crystal-oscillator stability.
* '''Accuracy:''' ± 1 count ± crystal-oscillator stability
* '''Input Impedance:''' 1 MΩ shunted by 50 pf 100 kΩ shunted by 500 pf, switch selected.
* '''Input Impedance:''' 1 MΩ // 50 pF, or 100 kΩ// 500 pF, switch-selected


==Links==
==Links==

Latest revision as of 17:55, 16 April 2024

General Radio 1150-B
Digital frequency meter
General Radio 1150-B Digital Frequency Meter

Available from 1965 to 1965

Manuals

Manual Needed

Catalog History
 Document Year Page
Catalog S 1965 121
(All manuals in PDF format unless noted otherwise)

The General Radio 1150-B Digital Frequency Meter, a general-purpose frequency meter and event counter, was only available in Catalog S (1965). It is an improvement on the 1150-A with higher frequency range and trigger control.

The display consists of five "Numerik" incandescent readouts (see IND-0300 and IND-1801 for details). It is interesting to note that if a lamp fails, the counter will stop at that digit because the lamp is part of the counting circuit.

Specifications

  • Frequency Range: 10 Hz to 400 kHz
  • Sensitivity 0.1 Vp-p at 100 kΩ or 1 Vp-p at 1 MΩ
  • Accuracy: ± 1 count ± crystal-oscillator stability
  • Input Impedance: 1 MΩ // 50 pF, or 100 kΩ// 500 pF, switch-selected

Links

Photos